default settings:
COM0: 19200, 8N1
COM1, COM2: 9600, 8N1
’standard Meinberg’
time string per second
mode of operation ’if sync’
Time Code
Outputs:
modulated via BNC-connector:
3 V
pp
(MARK), 1 V
pp
(SPACE) into 50
Ω
unmodulated via 16-pin terminal:
Field effect transistor with internal pull-up (1 k
Ω
) to +5 V
Data of transistor:
Uds
max
= 100 V, Id
max
= 150 mA, P
max
= 250 mW
TTL into 50
Ω
RS422
DCF77 Emulation:
AM-modulated 77.5 kHz carrier frequency
usable as replacement for a DCF77 antenna
output level approximately -55 dBm (unmodulated)
Power
Requirements:
GPS165DHS
20-60 V DC
DC-isolation 1.5 kV DC
GPS165DAHS
100-240 V DC
100-240 V AC, 50-60 Hz
fuse: 630 mA
Dimension:
GPS165/DHS
105 mm x 85 mm x 104 mm (height x width x depth)
GPS165/DAHS
105 mm x 125.5 mm x 104 mm (height x width x depth)
GPS165/DAHSx
105 mm x 165.5 mm x 104 mm (height x width x depth)
Connectors:
coaxial BNC connectors for antenna/converter unit, AM modulated
DCF77 output and modulated time code output
16-pole terminal block for connection of:
- pulse outputs
- power supply (GPS165DHS and GPS165/MOS/DHS only)
DAHS, MOS/DAHS: 5pol. Screwterminal
Ambient
Temperature:
0 ... 50
◦
C
Humidity:
85% max.
36
Date: 5th November 2019
GPS165XHS
Summary of Contents for GPS165
Page 1: ...MANUAL GPS165XHS DIN Rail GPS Receiver 5th November 2019 Meinberg Funkuhren GmbH Co KG...
Page 2: ......
Page 25: ...5 GPS165 Features 5 4 4 IRIG Standard Format GPS165XHS Date 5th November 2019 21...
Page 26: ...5 4 5 AFNOR Standard Format 22 Date 5th November 2019 GPS165XHS...
Page 62: ......