CONNECTORS:
HF BNC connector
D-SUB9 female connector
power cord receptacle
ANTENNA:
active external ferrite antenna in a plastic case
Length of the cable: up to 100m without amplifier
HOUSING:
Aluminium stack case
PHYSICAL
DIMENSIONS:
height x width x depth (72mm x 144mm x 132mm)
cutout in control panel: 140mm x 68mm
POWER
REQUIREMENTS: 230V AC ± 10%, 50mA or
5V DC ± 5%, 500mA or
12V DC (8V ... 14V), 500mA or
24V DC (18V ... 36V), 250mA
FUSE:
T 0.2A / 250V (@ 230V AC) or
T 0.5A (@ 5V, 12V und 24V DC)
AMBIENT
TEMPERATURE: 0 ... 50°C
HUMIDITY:
max. 85 %