6.8 Time String Out [TS. 0] or [TS. 1]
The generated time string can be selected in this sub menu. The list of available time string format is:
1.
Meinberg Standard
2.
Uni Erlangen (without position-datas!!)
3.
ATIS
4.
Sysplex 1
5.
SAT
6.
SPA
7.
Computime
8.
NMEA-RMC (without position-datas!!)
The format of the strings is described in the chapter "Time Strings".
6.9 Time Zone Out [TZ. 0] or [TZ. 1]
The time zone of the serial outputs COM0 or COM1 can be set here. With
B
the possible zones are displayed
in the following order: CET (Central European Time or CET), EET (East European Time) or UTC (without
DST). This setting is only relevant in the case of a DCF77-synchronized ANZ14. In case of a serial or NTP
synchronized ANZ14, the received time is always passed. With pressing the button
A
you can enter the next
submenu.
6.10 Sync In [In.]
The synchronization source of ANZ14 is defined here (see also chapter "Synchronization via Interface"). With
the button
B
the following sources are selectable:
1.
DCF - Synchronization via DCF77 (optional)
2.
232 - Synchronization via COM1 (RS232)
3.
422 - Synchronization via COM1 (RS422)
4.
LAN - Synchronization via Ethernet/NTP (optional)
28
Date: 28th October 2019
ANZ14/ANZ14DCF/ANZ14NET