Meilhaus Electronic Red-USB Iso User Manual Download Page 7

USB-Isolator U

ser’s Manual                             

_________________________________________________________________________________ 

_______________________________________________________________________________________ 
 

 

Case Material:

  Plastic non-conductive.  UL-94 HB flammability rating.

 

Dimensions

:  2.4

0” Length x 1.85” Wide x 0.925” High   

(60.96mmx46.99mmx23.495mm) 

Cable Length:  

Maximum cable length is 5 meters on each side. 

 

Connectors:

  High retention USB Type A (x 1) and USB Type B (x 1)  

connectors with minimum withdrawal force of 15 

Newton’s 

Data Rate:  

Selectable full-speed 12Mbps (

Default

) or low-speed 1.5Mbps.   

Transient Protection:  

Transient Voltage Suppressors are applied at both 

the PC and target device ports.  The metal cable shield is connected to 
signal GND though a ferrite. 

 

Power LED

 - Constant ON if power is on and unit is OK.  Blinking ON/OFF  

indicates unit is in current limit mode (>137mA) and the connected  
device is drawing too much power. 

 

Safety Approvals (All Pending):

  CE marked (EMC Directive 

2004/108/EC), UL Listed (UL508, ANSI/ISA 12.12.01, 2007), cUL Listed 
(Canada Standard C22.2, Nos. 142-M1987 and 213-M1987)

 

Electromagnetic Compatibility (EMC) - 
Minimum Immunity Per European Norm EN61000-6-2:2001: 

Electrostatic Discharge (ESD) Immunity:  

4KV direct contact and 8KV 

air-discharge to the enclosure port per IEC61000-4-2. 

Radiated Field Immunity (RFI):

  10V/M, 80 to 1000MHz AM and 

900MHz keyed carrier, per IEC61000-4-3. 

Electrical Fast Transient Immunity (EFT):

  2KV to power, and 1KV to 

signal I/O per IEC61000-4-4. 

Conducted RF Immunity (CRFI):

  10Vrms, 150KHz to 80MHz, per 

IEC61000-4-6. 

Surge Immunity:  

0.5KV per IEC61000-4-5. 

Emissions Per European Norm EN61000-6-4:2001 

Radiated Frequency Emissions: 

30 to 1000MHz per CISPR11 Class A 

WARNING:

  This is a Class A product.  In a domestic environment, this 

product may cause radio interference in which the user may be 
required to take adequate measures. 

 

Power Supply: 

Standard 5VDC power provided from the USB host  

computer up to 120mA of current. 

Current Limit:  

Isolator is equipped with a 200mA input limiter to isolator  

and this corresponds to ~137mA out.  Once limit is reached, power will  
open and retry momentarily, repeatedly until the current draw is less 
than 200mA. 

Isolation: 

 USB power and data circuits are isolated from each other for 

common-mode voltages up to 250VAC, or 354V DC off DC power 
ground, on a continuous basis (will withstand 1500VAC dielectric 
strength test for one minute without breakdown).  Complies with test 
requirements of ANSI/ISA-82.01-1988 for voltage rating specified. 

Operating Temp:  

 -40

C to +70

C (-40

F to +149

F). 

Relative Humidity:

  5 to 95%, non-condensing. 

 

 
 

 

SPECIFICATIONS 

Enclosure and Physical 
 
 
USB Interface

 

 
 
 

 

 

Controls and Indicators 

 

 

 

Agency Approvals 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Environmental 

 
 
 
 
 
 

Summary of Contents for Red-USB Iso

Page 1: ...Red USB Iso USB Isolator User s Manual Ausgabe May 2011...

Page 2: ...er USB cable Type A to Type B USB 2 0 compatible Changeable Data Rate allows selectable full speed 12Mbps Default or low speed 1 5Mbps Wide Ambient Operation from 40 to 70 C 40 to 158 F Hardened For H...

Page 3: ...esponding to 137mA out load Both signal lines are equipped with common mode filters and include transient protection USB is set to full speed 12 Mbps but can be jumped to low speed 1 5 Mbps for legacy...

Page 4: ...ice has been connected to the computer The power LED of the isolator should be ON and not blinking At this point you are ready to begin talking to your connected device TIP If your PC fails to detect...

Page 5: ...closure and this requires handling at an ESD safe work station Warning We do not recommend that you do this in the field as it invites potential damage to sensitive internal circuitry 1 Open enclosure...

Page 6: ...ot communicate with device connected through the Isolator Your computer does not support the peripheral Your device does not support 12Mbps Try changing internal jumpers to low speed see page 5 You do...

Page 7: ...discharge to the enclosure port per IEC61000 4 2 Radiated Field Immunity RFI 10V M 80 to 1000MHz AM and 900MHz keyed carrier per IEC61000 4 3 Electrical Fast Transient Immunity EFT 2KV to power and 1K...

Page 8: ...hotocopying recording or otherwise without the prior written permission of Meilhaus Electronic GmbH All the information included in this user s gide were put together with utmost care and to best know...

Reviews: