![Meilhaus Electronic ME-630 Series Manual Download Page 25](http://html1.mh-extra.com/html/meilhaus-electronic/me-630-series/me-630-series_manual_1766088025.webp)
5
Appendix
A
Specification
PC Interface
Bus system
PCI-Bus (32
bit, 33
MHz)
(depends on model)
CompactPCI bus (32
bit, 33
MHz)
PCI-Express x1, Specification Rev. 2.0
Plug&Play operation
fully supported
Relays
Number
8 resp. 16 form C relays
Relay type
NAIS APE3005 or compatible compliant
with EN 60255, EN 60335, EN 60730,
EN 60950, EN 60065, EN 50178
Permanent load
DC: max. 30
VDC/2
A;
AC: max. 30
VAC/2
A
Peak load
short time up to 30
V/3.5
A
(see also chapter “3.3
Resistance per relay channel
type
typ. 200
m
Ω
; max. 250
m
Ω
Isolation resistance
min. 103
M
Ω
at 500
VDC
Breakdown voltage
contact to contact: 1.000
V
contact to coil: 4.000
V
Operating time
ca. 5
ms (depends on contact rating)
Release time
ca. 3
ms (depends on contact rating)
Switching cycles
>
5
x
106
Monitoring
Relay registers can be read back by
software.
Digital Inputs (TTL)
Number
8 (only ME-630 „Standard“)
Input level (TTL)
low: 0
V…+
0.8
V (I
IL max.
= ±10
µA)
high: +
2.0
V…+5.5
V (I
IH max.
= ±10
µA)
Reference to ground
PC ground (PC_GND)