9760465
26 / 56
Local fuse protection
The machine must be fused appropriately for the rated current shown on the de-
scriptive plaque. The electrical connection must be fused as a separately fused cir-
cuit (final circuit). Take note of the connection variant.
The requirements for limiting voltage changes, fluctuations and flicker in accordance
with DIN EN 61000-3-11 for the dishwashers H 500 M2 and U 500 M2
are fulfilled if
the network has a current-carrying capacity of ≥
100
A.
Protective equipotential bonding
The screw for the potential equalisation
is located on the back of the machine
near the media connections.
The potential equalisation connection must be carried out in accordance with the
requirements of the local electricity supply companies and all applicable local regula-
tions (in Germany VDE 0100 Part 540). Incorporate the machine and any conductive
substructures and table systems into the local potential equalisation system.
6.2
Transport
WARNING
– danger of injury due to machine tipping
• Only qualified personnel may carry out transport works.
• Please note safety notices on the packaging.
• Always transport the machine on a wooden frame only.
• Wear protective gloves and safety shoes.
The packaging is specifically designed to allow the appliances to be moved safely
and securely using a pallet jack or a sack truck. For safe transport, the dishwashing
machine is supported by a special square-timber frame.
• Execute transport carefully.
• Open packaging using a suitable tool.
• Unpack the dishwashing machine only after transport is completed.
Summary of Contents for UPster H 500 M2
Page 55: ...55 56 9760465 13 Notes...