55 / 64
9763258
GiO MODULE on rear panel of machine
The pre-filter is freely accessible and is located close to the dishwashing machine.
Separately positioned GiO MODULE
The pre-filter is under a cover on a separately positioned GiO MODULE. No tools are required to unfasten
the cover. Unscrew 2x M5 nuts under the cover and then the cover can be removed.
Replace filter cartridge (dishwashing machine is disconnected from power and water supply)
1. Use key to unscrew casing by turning clockwise.
Position base drip tray!
2. Empty water and remove used filter cartridge.
Summary of Contents for M-iClean U