MeiG_SLM156_Hardware Design Manual
MeiG Smart Technology Co., Ltd
49/63
6.3 Working Temperature
It is recommended that you use SLM156 at -30
℃
~+75
℃
and take temperature control measures when
applications are in the harsh environment conditions. At the same time, a limited operating temperature
range of the module should be provided. Under this temperature conditions, some of RF indicators may
exceed. It is suggested that you store the applications under certain temperature conditions. Modules
beyond this range may not work or are damaged.
Table 25 Temperature range
Parameter
Min
Typical
Max
Unit
Operating temperature
-30
+25
+75
℃
Limited operating temperature
-40~-35
75~+85
℃
Storage temperature
-45
+90
℃
6.4 Electrical Characteristics of Interface Operation Status
VL: logical low level
VH: logical high level
Table 26 Logical level of normal digital IO signal
Signal
VL
VH
Unit
Min
Max
Min
Max
Digital input
-0.3
0.3*Vpin_min
0.3*Vpin_max
Vpin_max
V
Digital output
GND
0.2
Vpin_min-0.2
Vpin
V
Note:
Vpin_min=1.45V, Vpin_max=2.0V (Vpin is high level digital interface, Vpin=1.8V)