MeiG_SLM156_Hardware Design Manual
MeiG Smart Technology Co., Ltd
18/63
USIM_CLK
66
D
O
USIM card
clock line
1.8V USIM:
VOLmax=0.45V
VOHmin=1.35V
-
USIM_RST
65
D
O
USIM card
reset line
1.8V USIM:
VOLmax=0.45V
VOHmin=1.35V
-
USIM_DETECT
68
DI
USIM card
detection
VILmin=-0.3V
VILmax=0.6V
VIHmin=1.2V
VIHmax=2.0V
1.8V power
domain, don’t
use NC
Main serial port
Pin name
Pin number
I/O Description
DC features
Note
UART_RX
41
DI
Moduel
receives data
VILmin=-0.3V
VILmax=0.6V
VIHmin=1.2V
VIHmax=2.0V
1.8V power
domain, if
unused, keep it
open
UART_TX
40
D
O
Module sends
data
VOLmax=0.45V
VOHmin=1.35V
1.8V power
domain, if
unused, keep it
open
UART_CTS
43
D
O
Module clears
sending data
VOLmax=0.45V
VOHmin=1.35V
1.8V power
domain, if
unused, keep it
open
UART_RTS
42
DI
DTE asks
sending data
VILmin=-0.3V
VILmax=0.6V
VIHmin=1.2V
VIHmax=2.0V
1.8V power
domain, if
unused, keep it
open
UART interface
Pin name
Pin number
I/O Description
DC features
Note
TX _DBG
36
D
O
Module sends
data
VOLmax=0.45V
VOHmin=1.35V
1.8V power
domain, if
unused, keep it
open
RX_ DBG
37
DI
Module
receives data
VILmin=-0.3V
VILmax=0.6V
VIHmin=1.2V
VIHmax=2.0V
1.8V power
domain, if
unused, keep it
open
PCM interface