MOISTURE METER KC-321C

 

Pagina - 2 

 

 

 

Display Screen Illustration

 

 
A- Low battery indicator 
B- Data retention indicator 
C- MAX symbol 
D- MIN symbol 
E- Celsius 
F- Fahrenheit 
G- Probe temperature T2 / Wet bulb temperature 
H- Wet bulb indicator 
I- Condensation temperature difference 
J- Probe temperature 
K- Ambient temperature T1 / Dew Point (PR) 
L- Dew point indicator 
M- External / internal temperature difference = T1 - T2 
N- Ambient temperature indicator T2 
O- Relative humidity Reading 
 

Operating Instructions 

 

1.  Unscrew and open the battery cover, insert a 9V battery and replace the battery cover. 
2.  Turn the probe protection cap as indicated by the arrow, and make sure the sensor is fully exposed. To ensure a 

stable reading, place the device in the environment to be tested for at least one minute. The relative humidity will 
be displayed at the top of the LCD screen, while the temperature is displayed at the bottom. The display will turn 
off after 10 seconds of inactivity. Press any button to turn it back on. 

3.  Change  the  units  to  Celsius  or  Fahrenheit  by  pressing  the  C/F  button.  "F"  and  "C"  will  appear  on  the  display 

depending on the unit chosen. 

4.  Plug  the  external  probe  into  the  device  port  J  (indicated  in  the  product  details)  to  measure  the  surface  of  the 

object and the internal temperature. 

5.  If the external probe is not connected, press the DEW button and the temperature will appear on the LCD display 

changing between temperature T1 and dew point only. If the external probe is connected, press the  DEW button 
and the LCD will show the difference between temperature T1, dew point, ambient temperature and 

Δ

T = T1 - T2. 

6.  If  the  external  probe  is  not  connected,  press  the  WBT  button  and  it  will  only  display  the  wet  bulb  temperature 

reading. If the external probe is connected, press the WBT button and the LCD display will show the difference 
between the condensing temperature and the wet bulb temperature. If the external probe is removed, it will only 
show the wet bulb temperature reading. 

7.  Press  the  MAX/MIN  button  to  get  the  maximum  and  minimum  temperature  and  humidity  readings.  Press 

continuously until the "MIN" and "MAX" symbols are not displayed to exit the MAX/MIN mode. 

8.  Press  the  HOLD  button  to  set  the  current  temperature  and  humidity  values.  Press  again  to  get  the  dynamic 

readings of these values. 

9. 

 It will appear on the LCD screen if the battery is low. 

10.  Press and hold the power button for 3 seconds to turn off the device. When the auto power off mode is active, the 

device will turn itself off in 20 minutes. Replace the protective cap when the device is turned off. 

11.  The auto power off mode can be turned off. Press the HOLD button first and then press the ON/OFF button to 

turn on the device. The auto power off mode is then deactivated. 

 
 

Instructions for use 

 

 

1. Do not use this product if the manual has not been read previously. 

 

2.  To ensure accuracy, remove the protective cap and make sure the sensor is fully exposed before taking 
any readings. 

 

3.  Remove the battery before storing the device for a long period of time. 

 

4.  To  ensure  accuracy  after  calibration,  do  not  expose  the  sensor  to  a  saturated  environment  for  a  long 
period of time. 

 

5.  To avoid damage, do not use the device near the following locations: 

 

- Dirty or Steamy Places 

 

- Electromagnetic fields 

 

- Static environments 

 

- Sudden temperature changes 