![Megger L1070 Instruction Manual Download Page 14](http://html1.mh-extra.com/html/megger/l1070/l1070_instruction-manual_1765379014.webp)
M
AVTM651070 Rev B Nov 2006
6
Transmitter
Operating frequency:
82 kHz, 8 kHz, 815 Hz and BOTH (815Hz/82kHz)
AC LOAD RESISTANCE MEASUREMENT.LOW BAT
Low battery warning modulated or output signal every 20 seconds.
Load matching
Automatic from 5 to 2000
Ω
Output power:
Normal
High
815 Hz
0.6 W
2.0 W
8 kHz
0.6W
2.0 W
82 kHz
0.2 W
1.0 W
BOTH
0.12 W+.06 W
1.33 W+0.67 W
Battery type:
1070
Disposable - Eight 1.5 V, D-size alkaline
1071
Rechargeable - One 12 V, 7 Ah maintenance-free, sealed lead-acid
Battery life:
Disposable
Continuous
8 to 15 hr depending on load, frequency & power setting
Intermittent
40 to 60 hr depending on load, frequency & power setting. 25%
duty cycle average
Rechargeable
Continuous
10 to 20 hr depending on load, frequency & power setting.
Intermittent
50 to 70 hr depending on load, frequency & power setting. 25%
duty cycle average.
Operating and storage
temperature range:
-4°F to +133°F (-20°C to +55°C).
Dimensions:
16 x 6.32 x (5-6) in. (40.6 x 16 x (12.7-15.2) cm) (L x W x H)
Weight:
8 lb (3.6 kg) with disposable alkaline cells
11.5 lb (5.2 kg) with rechargeable sealed lead-acid cells