VoltSeek
Voltage Range of High
Sensitivity :
80 V ~ 1000 V (At the top edge of the jaw)
Voltage Range of Low
Sensitivity :
160 V ~ 1000 V (At the top edge of the jaw)
Temperature
Range
OL Reading
Resolution
Accuracy
-40.0 °C – 400.0 °C 440.0 °C
0.1 °C
± (1% + 20D)
-40.0 °F – 752.0 °F
824.0 °F
0.1 °F
± (1% + 36D)
The accuracy does not include the accuracy of the thermocouple probe.
Accuracy specification assumes surrounding temperature stable to ±1 °C.
For surrounding temperature changes of ± 2 °C rated accuracy applies after 2 hours.
Overload Protection :
AC/DC 1000 V
Specification PVHV1 (4mm plugs) and PVHV2 (MC4) test leads
Input Impedance :
10 MΩ
Overvoltage Category :
CAT II 1000 V AC ,1500 V DC CAT III 1000 V,
CAT IV 600 V.
Pollution Degree :
2
Exposed probe tip length :
Test probe: 18 mm to 3.5 mm
(0.70 inch to 0.14 inch)
Environmental ratings :
-10 °C to 45 °C (-4 °F to 113 °F), 80% R.H.
Altitude :
2000 m (6,562 ft)
Safety Standard :
EN61010-031
Product manufactured in Taiwan
DCM1500S User Guide
36