UP-PN-
II
v0.8 28
n
Parameter
Example
0
Product name
Prod.: UP-PNII-240
1
Name & version of software
Soft.: F189v1.1
2
Manufacturer’s name
Maker: MEGATRON
3
Date & Time
Clock: JJMMAAHHMNSS
4
Paper input (scaled)
Paper: 1023
5
Power voltage
Volt: 5.452
6
Paper end sensor
19h (Present) ou
17h (Absent)
•
GS u n data
1
.. data
n
(1D 75 Hex=29 117 Dec)
Transmits data to the host on serial.
This command transmits on serial the “n” followed bytes (n<24). This
command is mainly employed with messages and logo, in order to initialize or
remote an external equipment like a measurement instrument.
If the size of data is greater than 24, you must divide them in segments.
4.5.7 S
PECIAL
COMMANDS
•
ESC V n (1B 56 Hex=27 86 Dec)
Synchronization character.
When whole previous data have been printed, the sync character “n” is sent
to the host on serial. The host is then certain that the printout is OK.
•
GS v n (1D 76 Hex=29 118 Dec)
Returns status to the host.
When this command is entered, one of the 6 status selected by the 2 LSB
bits of “n” is sent to the host on serial. The string is ended by CR character
(0Dh)