Wood-pellet burner
Nani 35
7. By pressing the button “
MODE
/ “ once changes the operation from “
Stop
” to
“
ignition
”. By pressing the button “
MODE
/ “ changes the operation from
“
Ignition
” to “
Automatic
”.
** The frequency of cleaning burner's chamber is depended on wood pellet's
quality. If premium pellet is used, It is suggested the burner's chamber to be
cleaned once a week.
15. Restart the burner after an error
1. Turn off the burner by using the electric switch the burner is connected
2. Open the boiler's door and check the burners tube.
3. Remove any ashes and impurities from burners fire chamber.
4. Close the door and switch on the controller by using the electric switch
the burner is connected
5. By pressing the button “MODE/ “ once changes the operation from “Stop” to
“ignition”. By pressing the button “MODE/ “ changes the operation from “Ignition”
to “Automatic"
16.
Feeder's filling procedure
1. Remove the plastic tube connection the burner with the feeder
2. Burner must be at stop mode. So, “Stop” appears on the LCD scree
3. By pressing the button “
MODE/
“ once changes the operation from “
Stop
” to
“
ignition
”.
4.
“CHOICE FUNCTION-/+”
appears on the LCD screen
5. Press the button
to start the feeder
6. Feeders operation lasts 11min (Manufacturer's setting / Feeder's filling time"
7. When the wood-pellet starts to come out of the feeder, press
to stop
the feeder
8. Connect the feeder with the burner, by using the plastic pipe.
9. If the "Feeder's filling time" is not enough, press
to start the feedder
again
20