Wood-pellet burner
Nani 35
8.
Parameter's
To move round the menu and to set particular parameters there are four buttons placed on
the driver's panel:
“MODE/ ”
,
“MENU/OK”
,
“+”
,
“-”
. The parameters chosen by the
user are divided into four groups: (A)
“CH FURNACE SETTINGS”
, (B)
“WUW BUFFER
SETTINGS”
, (C)
“BURNER SETTINGS”
, (D)
“DRIVER SETTINGS”
. The division of
particular parameters in groups is shown in the
“Settings' table”.
➢
CH FURNACE SETTINGS
(A)
FUNCTION
NO.
FUNCTION
NAME
SETTING
UNIT
SETTING
RANGE
MANUFACTURER
SETTING
1
HEATING WATER
TEMPERATURE
º
C
35 - 85
65*
2
CH PUMP ACTIVATION
TEMPERATURE
º
C
20 - 60
35*
3
CH FURNACE
HYSTERESIS
º
C
1 - 20
5*
4
FURNACE
MODE
---
Winter/Summer
Winter*
➢
WUW BUFFER SETTINGS
(B)
FUNCTION
NO.
FUNCTION
NAME
SETTING
UNIT
SETTING
RANGE
MANUFACTURER
SETTING
1
WUW BUFFER
TEMPERATUR
º
C
20 - 80
40*
2
WUW SURPLUS
TEMPERATURE
º
C
5 - 20
10*
3
WUW
PRIORITY
---
Yes/No
No*
➢
BURNER SETTINGS
(C)
FUNCTION
NO.
FUNCTION
NAME
SETTING
UNIT
SETTING
RANGE
MANUFACTURER
SETTING
1
BURNER POWER
(WORK)
kW
10 - 35
30*
2
BURNER POWER
(MAINTAIN)
kW
2- 9
3*
3
BURNER
MODE**
---
Continuous/
Single/Analogue
Continuous*
4
SELF CLEANING FREQUENCY
TIME
Min
10-480
240
10