Megatherm wood-pellet burner
MPB serie's
application.
E12. IGNITION STABILIZATION
When ignition has occurred, the air-fan works for the time, which has been set by this
parameter. This operation drives the ignition gases out of the boiler faster.
Manufacturer Advise:
30-60sec
E13. MAXIMUM BURNER POWER
In this parameter the installer can set the maximum burner power, where the user can set
by visiting the burner's menu. This prevents the user to set the burner at a maximum
power, than the one it is required by the system.
Manufacturer Advise:
40kW
E14. MINIMUM BURNER POWER
In this parameter the installer can set the minimum burner power, where the user can set
by visiting the burner's menu. This prevents the user to set the burner at a maximum
power, than the one it is required by the system.
Manufacturer Advise:
9kW
E.15 MINIMUM FURNACE TEMPERATURE
In this parameter the manufacturer sets the minimal temperature of the furnace which can
be set by the user. The activity of the room thermostat causes the setting of the boiler into
this parameter. The minimal temperature of the boiler is set in the bracket of 20 to 60 °C.
Manufacturer Advise:
35
o
C
E16. SENSOR TYPE
In this parameter the installer can choose between KTY ant PT 1000 temperature sensors.
KTY is the default sensor which is used for measuring temperatures up to 100
o
C.
The PT 1000 sensor is given by the manufacturer under request and it is used to measure
temperature higher than 100
o
C (industrial applications).
Notice: Nani 35 is not suggested to be installed in industrial applications.
E.17 EXTERNAL CONTROL (room thermostat)
This parameter, it is activated only if room thermostat it is connected on the controller
If external control No
(Manufacturer's settings)
:
1. When thermostat is ON, the burner works at the maximum power it is set.
17