7. Software Update
34
35
ENGLISH
ENGLISH
6. Tuner
6.2 Tuner Test
7.1 USB
Enter the below valid parameters to check the tuner lock sattus.
• Source - To select the Tuner source
• Frequency - To enter the fixed frequency.
• Symbol rate - To enter the fixed symbol rate(1000 to 65000kSps).
• Polarization - To select Horizontal / Vertical.
• LNA - To attenuate the signal from 0 to 16db.
In order to support S/W upgrading, we have supported the below upgrading modes,
• S/W download via USB
• S/W download via OND
• S/W download via WEB UI
The S/W Upgrade via USB option used to download the latest software by USB memory
device
Procedure for S/W Upgrade via USB:
• Format (FAT32 file format) the USB stick and create the folder name „Update“
• Copy the .usb images directly in to the folder name „Update“ and insert the USB
memory device in the STB USB port.
• Select the S/W Upgrade via USB option from the menu.
Note:
If USB media is not inserted and when user select „Software Upgrade via USB“ then
above message will be displayed.