background image

 

 

                                                         

 

-25- 

Using the IR Pen 

 

Unscrew the rear cap to open and insert two AAA size batteries into the 
compartment.    Please note the correct polarity of the battery. 

1.

 

Click 

Lightly tap the pen tip once on the menu or icon of the screen. 

2.

 

Double Click 

Light tap the pen tip twice on the same place of the screen. 

3.

 

Drag 

Lightly press the pen tip on an icon and move it, placing it on the screen 
within the active area. 

4.

 

Writing and Drawing 

Use the pen like a normal pen. 

 

Note: As the operation of the M-Pointer depends on identification of the 
IR dot as emitted by the pen by the camera on the main unit, it is 
essential that the human body or the hand or arm do not block the path 
between the camera and the pen tip. 
 

Setting Up 

 
1.

 

Place the M-Pointer at a distance to the screen of about the width of the 
projected image.    The M-Pointer works fine over a wide range of 
positions. 

2.

 

Plug the Wireless Dongle onto a USB 2.0 port on your PC for wireless 
operation or connect the port on the rear of the Main Unit to the USB 
port on your PC. 

3.

 

Turn the camera head up by rotating outwards.    There is a magnetic 
switch inside the M-Pointer.    The unit will turn On immediately when 
the camera is rotated outwards.    Please place the camera head back to 
its closed position to turn Off the unit.    This will save the battery 
operating time. 

4.

 

Rotate the camera head to a position so that the center of the camera is 
approximately in line with the center of the screen.    This does not 
require very precise setting. 

5.

 

Click on the M-Pointer Driver to start the software. 

 

Note:    Please charge up the battery after the box is opened 
by connecting the M-Pointer to the USB port of your PC. 

Summary of Contents for M-POINTER ML11

Page 1: ... 1 M POINTER Wireless Virtual Interactive Whiteboard User s Manual The content of this manual is subject to change without prior notice All rights reserved ...

Page 2: ...nction 5 Installation Software Installation 6 Using the Software 10 Calibration 10 Options 13 Functions Annotation 14 Whiteboard 18 Keyboard 20 Shortcut 21 PPT 22 Tools 23 Using the IR Pen 25 Setting Up 26 Changing RF Communications Channel 27 Troubleshooting 30 Specifications 31 ...

Page 3: ...disconnect the USB cable After making sure that the smoke or odor has stopped contact your dealer for repairs Do not attempt to make repairs yourself Do not open the cabinet There are no user serviceable parts inside Should the unit become faulty please contact your dealer Do not press the pen too hard onto the wall or screen Cleaning Do not use abrasive chemical or solvents for cleaning Use only ...

Page 4: ...hrough this booklet in details Please also keep it in a handy place for future reference when necessary Package Contents Before you start please check the package contents if any are missing please contact your dealer immediately IWB Main Unit IR Pen RF Dongle USB cable User s Instructions Software disk ...

Page 5: ... M Pointer is turned On 2 Rotating Camera Head 3 USB Port Used for charging the internal battery or for direct connection with PC 4 Tripod Mount Use with Tripod or with the Ceiling Mount Kit 5 Pen Tip 6 USB Dongle Use for Wireless Connection of M Pointer with PC ...

Page 6: ...river program is on the CD ROM Turn on your PC and insert the CD into the CD ROM driver Follow the instruction to install the program 1 click MPOINTER EXE to start the installation 2 Accept the terms and conditions of the license agreement then click NEXT ...

Page 7: ... 7 3 Set the location to install the MPOINTER software then click INSTALL to start the installation ...

Page 8: ... 8 4 Click FINISH to complete the installation ...

Page 9: ... 9 ...

Page 10: ...ngle into the USB port of your PC Start the MPOINTER application software The icon will appear in the task bar on the bottom of the screen and the menu will display as follows Before using the functions of the M Pointer the unit needs to be set to read the screen size Click on then select CALIBRATE ...

Page 11: ...ll move to the next calibration point 075 0 5 and 0 3 modes When the camera is not able to cover the whole screen that is the top parts of the screen is out of reach then use these modes 0 75 mode the crosshairs start to appear the way up the screen 0 5 mode half way up and 0 3 mode 1 3 the way up For greater accuracy use the 25 and 16 point calibration modes ...

Page 12: ...small window of the whole screen will appear as in the following picture Calibrate as in the main calibration procedure but for the small window This is particularly useful in situations when the entire screen is large and the top of the screen is out of reach ...

Page 13: ... 13 OPTION Basic settings for the M Pointer The options can be changed for personal preferences or left as they are ...

Page 14: ... 14 Functions The following describes the functions of the M Pointer software ANNOTATION PEN A selection of different pen styles ERASER Selecting ways to delete annotations GRAPHICS Function to draw ...

Page 15: ...n the screen Input text by keyboard Move cursor to location where you would like the text to be placed Press and hold LEFT mouse button then move mouse to open required box size To increase or reduce pen width or text size Selects pen or text color Previews pen thickness color and text size ...

Page 16: ... 16 ERASE erase at the cursor position Erase an enclosed area Cancels last operation Reverse the cancelled operation Clear all annotations ...

Page 17: ... 17 GRAPHICS Use this function to draw various regular shapes on the screen ...

Page 18: ...files Each numbered tile can be selected and displayed as the main tile on the screen Can draw write on each file and the whole set can be stored in the SAVEFILE folder Prepared files can be imported to aid presentations Files are stored in the following format SaveFile yy mm dd mi zt WhiteBoardTemp where yy is year mm is month dd is day mi is minutes ...

Page 19: ... 19 ...

Page 20: ...IR pen equivalent to operate as the RIGHT BUTTON of a mouse Sets the IR pen equivalent to operate as the DOUBLE CLICK action of a mouse Closes opened applications Provides options RESTORE MINIMIZE ESC and KEYBOARD See Below ...

Page 21: ... 21 SHORT CUT The options are equivalent to computer commands minimizing restoring and escape functions for applications windows A soft keyboard to aid input ...

Page 22: ...otate PPT or WPS files SAVE Option to save annotated active files to desired storage locations 3DPPT Same function as 3Dboard but instead displays the pages of the PPT as a series of PNG files which are stored in a PowerPoint folder ...

Page 23: ... 23 TOOLS Capture and display images Images capture a selected area of the screen capture whole screen print selected image select and display previously stored images ...

Page 24: ... 24 MEDIA Browse pictures with the 3D board SCREEN stop recording screen activity pause recording screen activity playback captured video Captured video is in AVI file format ...

Page 25: ... the M Pointer at a distance to the screen of about the width of the projected image The M Pointer works fine over a wide range of positions 2 Plug the Wireless Dongle onto a USB 2 0 port on your PC for wireless operation or connect the port on the rear of the Main Unit to the USB port on your PC 3 Turn the camera head up by rotating outwards There is a magnetic switch inside the M Pointer The uni...

Page 26: ... both the main unit and RF dongle is powered OFF connect the USB cable from the main unit to a computer invoke the MPointer software click on then click on EFFECT SETTINGS on the computer keyboard press Ctrl and F simultaneously to give obtain the following screen ...

Page 27: ...he bottom of the settings screen to finish Close the MPointer software and disconnect the main unit from the computer Set RF DONGLE plug the RF dongle to an unused USB port on the computer invoke the MPointer software click on then click on EFFECT SETTINGS on the computer keyboard press Ctrl and F simultaneously to give obtain the following screen Click on SETTING THRESHOLD pull down options then ...

Page 28: ...reen bar to channel 100 same channel as the main unit then on the right click on OK Click on the OK at the bottom of the settings screen to finish Close the MPointer software then remove dongle from computer to finish ...

Page 29: ... 29 Installation Diagram ...

Page 30: ...on The M Pointer might have moved during installation Recalibrate Please do not change the resolution on your computer AFTER the driver software is opened Cursor moves about randomly Point the unit away from bright natural light and areas of high IR emission Two or more wireless IWB units operate at the same time Set one of the wireless units to operate on different RF channel see setting RF chann...

Page 31: ...olution pixels 300 000 Native 1 2M expanded Calibration Method 4 16 25 points selectable Interface USB 2 0 Accuracy Less than 1 5 pixels Uniformity 85 Operating Distance Standard Throw Short Throw Wireless Distance 8 m open space Battery Operating Time More than 8 hours Power Consumption Approx Dimension WxLxH 60x130x30mm Weight 173g inclusive of IR pen and rf dongle ...