LIGHTING INSTRUCTIONS
TO TURN ON THE HEATER
1. Turn the control knob to the “OFF” position
2. Turn on the valve on the gas supply cylinder completely.
3. Press and turn the variable control knob to “LOW” position (counter-clockwise 90º)
4. Press down the variable control knob and hold for 30 seconds. While holding down
the variable control knob after the pilot flame lights.
Note:
•
If a new LP gas cylinder has just been connected, please allows at least one
minute for the air in the gas pipeline to purge out through the pilot hole.
•
When lighting the pilot flame make sure that the variable control knob is
continuously pressed down while pressing the igniter button. Variable control
knob can be released after the pilot flame lights.
•
Pilot flame can be watched and checked from the small round window with
sliding lid located at the bottom of the flame screen (to the left or right side of the
controller).
•
If the pilot flame does not light or it goes out, REPEAT STEP 3.
5.
After the pilot flame lights, turn the variable control knob to minimum position and
leave it there for 5 minutes or more before turning the knob to desired temperature
position.
6. If burner still does not stay lit, then:
a) Push in gas control knob and turn counter clockwise to the "LOW" position.
b) Keep depressing the control knob, put long stem lighter into the ignition hole on
the emitter screen to light the burner.
TO TURN OFF THE HEATER
1. Push and turn the variable control knob to “OFF” position.
2. Turn off the valve on the LP gas supply cylinder completely.