HEATER STAND AND LOCATION
•
The heater is primarily for outdoor use only.
Always ensure that adequate fresh air
ventilation is provided.
•
Always maintain proper clearance to
combustible materials, i.e. top 2m and sides
2m minimum. Heater must be placed on
level firm ground.
•
Never operate heater in an explosive
atmosphere like areas where gasoline or
other flammable liquids or vapors are
stored.
•
To protect heater from strong wind, anchor the base securely to the ground with
screws.
GAS REQUIREMENTS
•
For use with LP Gas mix only.
•
LP Gas regulator must be a 2, 8kPa regulator that complies with the requirements of
SANS1237
.
•
The hose assembly to be used must conform to local standard codes.
•
The installation must conform to local codes, or in the absence of codes, with the
standard for storage and handling of liquid petroleum gases. SANS 1539:2012
•
A dented, rusted or damaged LP gas cylinder may be hazardous and should be
checked by your cylinder supplier.
•
Never use a LP gas cylinder with a damaged valve connection.
•
The LP gas cylinder must be arranged to provide for vapor withdrawal from the
operating cylinder.
•
Never connect an unregulated LP gas cylinder to the heater.