10
INSTALLATION INSTRUCTIONS
DISCONNECTING THE LP Gas CYLINDER
1. Turn the grill burner valves “OFF” and make sure the grill is cool.
2. Turn the LP gas cylinder valve “OFF” by turning clockwise until it stops.
3. Detach the regulator assembly from the cylinder valve by turning the wheel nut clockwise.
4. Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the
cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of LP
gas.
LEAK TESTING
GENERAL
Although gas connections on the grill are leak tested prior to shipment, a complete leak test must be performed at
the installation site. Before each use, check all gas connections for leaks using the procedures listed below.
If the smell of gas is detected at any time, you should immediately check the entire system for leaks.
BEFORE TESTING
Make sure all packing materials have been removed from the grill, including the burner tie-down straps.
WARNING
Check all gas supply fittings for leaks before each use. Do not use the grill until all connections have been
checked and do not leak. Do not smoke while leak testing. Never leak test with an open flame.
Make a solution of one part liquid detergent and one part water. You will need a spray bottle, brush, or rag to
apply the solution to the fittings. For the initial leak test, make sure the LP Gas cylinder is full.
TO TEST
1. Turn the burner valves off.
2. Turn the LP gas cylinder valve counterclockwise to open the valve.
3. Apply the soap solution to all gas fittings. Soap bubbles will appear where a leak is present.
4. If a leak is present, immediately turn the gas supply “OFF” and tighten leaky fittings.
5. Turn the gas ba
ck “ON” and recheck.
6. Should the gas continue to leak from any of the fittings, turn the gas supply “OFF” and contact customer
service at (+27) 12 802 1515.
7. If there is evidence of excessive abrasion or wear, or the hose is cut, it must be replaced prior to the outdoor
cooking gas appliance being put into operation.
Only those parts recommended by the manufacturer should be used on the grill. Substitutions will void the
warranty.
WARNING
1. Storage of an outdoor cooking gas appliance indoor is permissible only if the cylinder is
disconnected and removed from the outdoor cooking gas appliance.
2. Cylinder must be stored outdoors out of the reach of children and must not be stored in a
building, garage or any other enclosed area.
INSTALLER FINAL CHECK
Maintain specified clearance of 24 inches from combustible materials and construction.
All internal packaging has been removed.
The hose and regulator are properly connected to the LP gas cylinder.
The unit has been tested and is free of leaks.
The gas supply shutoff valve has been located.
WARNING
1. Do not store spare LP Gas cylinders under or near this appliance.
2. Never fill the cylinder beyond 80 percent capacity.
3. If the information in item 1&2 is not followed exactly, a fire causing death or serious injury may occur.