Manual function allows you to control the intensity of the LED’s side and bottom sepa-
rately via the display. Controls 1-4 are designated for the side led control and controls 5-
8 are for the control of the bottom led. Each section can be controlled by pressing
Set
Up
and using the
Up/Down
keys to select the color you would want. When using Manual
function and the unit is powered off and on the selected setting will return.
Manual
2.Green 1 : 255
3.Blue 1
001
4.White 1:
000
5.Red 2:
055
Settings
Fixture Setting, Press
Set Up
use the
Up/Down
keys to select what fixture setting you
would like to adjust press
Set Up
to enter that function.
Settings
1.Curve Select
2.Dimmer Speed
3.Dmx Fail
4.Dmx Sync
5.Lock
6.Fan
7.Factory
Linear
Square Law
Inv Square Law
S-Type
Curve Select:
This setting allows you to control the dimming type.
press
Set Up
use the
Up/Down
keys to select dim curve type.
Fast
Smooth
Dimmer Speed:
Select from Fast dimming or Smooth Slower dim-
ming. Press
Set Up
use the
Up/Down
keys to select Dimmer Speed.
Off
Hold
Manual
Program
DMX Fail:
This Setting allows you to select what function the LEDS
will do if DMX signal is lost during use.
Off
will turn all Dimmer chan-
nels to the 000 position.
Hold
will hold the last DMX command re-
ceived.
Manual
will revert back to the Manual setting.
Program
will
revert to the setting in the Program section of the display. Press
Set
Up
use the
Up/Down
keys to select the DMX Fail Options.
DMX Sync
On
Off
DMX Sync:
This function is used with older DMX Controllers that
have a slower DMX Signal refresh rate
Lock
On
Off
Lock:
To lock the display access you will need to engage this func-
tion. Press
Set Up
use the
Up/Down
keys to select. To Unlock the
display you must Hold the
Mode & Set Up
button at the same time for
seconds
Fan Speed
Fan Off
Sensor
Fan On
Fan:
There is 3 Fan Setting options.
Fan Off
will leave fan off, but will
reduce the LED intensity once reached a unsafe temperature.
Sensor
will engage the fan once needed.
Fan On
will leave fan turned on at all
times. Press
Set Up
use the
Up/Down
keys to select press Set Up to
confirm
Factory
Yes
No
Factory:
This function revert all setting to original factory setting.
Press Yes to continue and No to go back.
Information
Will price systems information
Version: 1.0
Temperature:28ºC
Work Time:00056h