Auto Speed
Main Menu
Auto Mode
>Auto Speed
Temperature
Press
Enter.
Select from 6 modes Press
ESC
to return to Main Menu.
(Note: If you want to have fixture remain on Auto Test do not press ESC and just power off
and on fixture to return to last setting)
Setting
Setting Control Options
Main Menu
Dimmer Speed
Temperature
>Setting
Config Menu
>Oled Back Light
DMX Fail
Dimmer Setting
To turn off display screen after 2 minutes of no use select
Disable
. To enable
screen to remain on when in use select
Enable
.
Config Menu
LCD Back Light
>DMX Fail
Dimmer Setting
To hold the last DMX command is case of DMX Signal loss select
Enable
. To have
the fixture DMX Setting at 0 if DMX signal is loss use
Disable
option.
Config Menu
LCD Back Light
DMX Fail
>Dimmer Setting
Select Dimmer Setting to be used for dimming type when used in Ch3 mode.
Linear
Square Law
Inv. Square Law
S Type
Config Menu
DMX Fail
Dimmer Setting
>Factory Reset
Restore fixture to original factory display settings
Temperature
This fixture is equipped with internal temperature sensors. Once head reaches a tempera-
ture of 96°the IP rated fan will engage