background image

Cleaning and Maintenance 

Installation Maintenance: 

The operator has to make sure that the unit is operating safely and has the installations and 

electronics checked by an expert every 2 years. 
 

The following points have to be considered during the inspection: 

1)  All screws used for installing the device or part of the device have to be tightly connected and must not be corroded. 

2)  There must not be any deformations on the housing, fixation and installation spots (ceiling, suspension, trussing). 

3)  Mechanically moved parts like axles and other must not show any traces of wearing and must not rotate with unbal-

ances. 

4)  The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments.  

Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any 

safety problems have to be removed. 

Disconnect from mains before starting maintenance operation! 

 

 
 

    Caution Danger to life! 

 
 
 
 

We recommend a frequent cleaning of the device.  Please use a moist, lint free cloth.  Never use alcohol or solvents! 

1)  The objective lens will require periodic cleaning on usage and environment.  Environment with foggers will require 

more periodic cleaning as fog fluid tends to build up residues, reducing the light output. 

2)  The cooling-fans should be cleaned monthly.  DO NOT blow high pressure air into fans as incorrect rotation can 

damage the fans operation. 

3)  The gobos, dichroic color filters and internal lenses may be cleaned with soft brush using soapy water. 

4)  The interior of the fixture should be cleaned using a vacuum. 

5)  We recommend proper lubrication of the motor wheel.  The quantity of the oil must not be excessive in order to avoid 

oil run outs when motor wheel rotate 

Note: 

There is no serviceable parts inside the device except for the fuse.  Maintenance and service operations are to be 

carried out by authorized dealers. 

Replacing the fuse:  

Only replace the fuse with the same type and rating. 

Replacing the power cable:  

If the power cable of this device becomes damaged, it has to be replaced by authorized 

dealers only 

Should you have further questions , please contact your dealer. 

11 

Parts List 

5200-LED-MOD-I 

LED Module Inner (segment) 

5200-LED-MOD-C 

LED Module Center 

5200-LED-MOD-R 

LED Module Reflective Ring (half) 

5200-LED-MOD-RC 

LED Module Reflective Center (1/3) 

5200-LED-MOD-O 

LED Module Outer Ring (half)  

5200-POW 

Power Supply 

5200-PCB-DRI-A 

PCB Driver A 

52000-PCB-DRI-B 

PCB Driver B 

5200-PCB-POW 

PCB for Power Distribution 

5200-BEZ-RIN 

Outer Ring Milky Diffusion Plastic 

5200-BEZ-CEN 

 

Center Globe Filter Plastic 

5200-PCB-MAI-DIS 

Display and Main PCB 

5200-FAN-X.W 

X.W-6010M24B Fan 

5200-HOU-NET 

Housing Net 

5200-HOU-KNO 

Housing base for Knob 

5200-KNO 

Knob 

5200-FAN-HW5 

HW5020B Fan 

5200-HOU-QUI 

Quick Release Clamp Mount 

3012-CON-3PI 

3 pin XLR In/Out 

3012-CON-5PI 

5 pin XLR In/Out 

3010-CON-POW-F 

Lequin Power Output White 

3010-CON-POW-M 

Lequin Power Input Blue 

Summary of Contents for Circa

Page 1: ...L Table of Contents Safety Information 2 Specifications 3 Main Power Connection 4 DMX 512 Connection 4 Main Control Menu 5 Rigging the Fixture 7 Accessories 7 DMX Profile 7 Cleaning Maintenance 11 Par...

Page 2: ......

Page 3: ...t 6 Maximum surface operating temperature 104 Protection Against Electrical Damage 1 Disconnect power before lamp replacement or servicing 2 For connection to main power supply proceed to page 4 3 Thi...

Page 4: ...White Amber Mode 3 17 Channels Dimmer Outer R G B Macro Macro Speed Outer Strobe Inner R G B Macro Macro Speed Inner Strobe Warm White Amber Reflective Center Center Strobe Mode 4 52 Channels Dimmer...

Page 5: ...gnal into a 5 pin XLR plug and plug it in to the last fixture on the signal run Pre manufactured terminator plugs are availa ble for purchase from your Mega Lite dealer P DMX T Cable USA Cable EU Pin...

Page 6: ...Channel mode of operation Use the up down keys to select Channel mode from Press Enter to confirm the setting Press ESC to return to Main Menu Channel Mode Main Menu Channel Mode Led Dimmer Led Strobe...

Page 7: ...n when in use select Enable Config Menu LCD Back Light DMX Fail Dimmer Setting To hold the last DMX command is case of DMX Signal loss select Enable To have the fixture DMX Setting at 0 if DMX signal...

Page 8: ...e a professional structural rigger When rigging the unit always be secured with a secondary safety attachment The installation location of the projector has got to be built in the way that it can hold...

Page 9: ...14 255 8 LED Color Inner Red LED intensity 0 255 255 9 LED Color Inner Green LED Intensity 0 255 255 10 LED Color Inner Blue LED Intensity 0 255 255 No Function 0 1 Fade Clockwise 2 24 Fade Counter Cl...

Page 10: ...24 LED Color Outer 8 Green LED intensity 0 255 0 25 LED Color Outer 8 Blue LED intensity 0 255 0 26 LED Color Inner 1 Red LED intensity 0 255 0 27 LED Color Inner 1 Green LED intensity 0 255 0 28 LED...

Page 11: ...214 255 27 LED Color Inner 1 Red LED intensity 0 255 0 28 LED Color Inner 1 Green LED intensity 0 255 0 29 LED Color Inner 1 Blue LED intensity 0 255 0 30 LED Color Inner 2 Red LED intensity 0 255 0 3...

Page 12: ...incorrect rotation can damage the fans operation 3 The gobos dichroic color filters and internal lenses may be cleaned with soft brush using soapy water 4 The interior of the fixture should be cleaned...

Page 13: ...ess or implied with respect to any product and Mega Systems specifically disclaims any warranty of merchantability or fitness for a particular purpose Mega Systems shall not be liable for any indirect...