Megalarm MEGA 2550 Installation Manual Download Page 6

 

This will become a 1 second pulse ground by activating channel 3 on the transmitter for two seconds. The 
current capacity of this wire is 200mA. This feature allows you to remote control the trunk release or 
another electric device. This output can also be programmed to provide the following type of output: 
1-second pulse, latched, timer control, and pager. (See Alarm Feature

 

III - 3 

Programming 

H8/10.Black / White wire – (-) 200mA Dome Light Control Output – 

This wire becomes grounded when the dome light control circuit is active. The current capacity of this wire 
is 200mA. This wire can control the operation of the interior lights. An optional 10 Amp relay can be used 
on this system for interior lights operation. 
a). Upon disarming, the interior lights will remain on for 30 seconds. 
b). If the vehicle is violated, the interior lights will flash for the same duration as the siren.

   

 
 

H4. 6 PIN DOOR LOCK HARNESS: 

Blue/White 

W ire: 

(30

) - Door Unlock Relay 

Blue/Red 

W ire: 

(87a)

 - Door Unlock Relay

Blue/Yellow 

W ire: 

(87)

 - Door Unlock Relay

 

Green/Red 

W ire: 

(87a)

 - Door Lock R elay

Green/White 

W ire: 

(30

) - Door Lock Relay

 

Green/Yellow 

W ire: 

(87)

 - Door Lock Relay

 

 

INSTALL NEW DOOR LOCK MOTORS 

+12V 

Green/ white 

Blue/ white 

Blue/ red 

Green/ red 

Green/ yellow 

Blue/ yellow

 

NEGATIVE TRIGGER DOOR LOCK SYSTEM

Blue / white

Green / white

Door Lock

M aster
Locking

Switch

Door unlock

Green / yellow

Blue / yellow

 

POSITIVE TRIGGER DOOR LOCK SYSTEM

Blue / white

Green / white

Door Lock

M aster
Locking

Switch

Door unlock

Green / y ellow

Blue / yellow

+ 12V

+ 12V

 

ALTERNATING DOOR LOCKS

 

+12V

Master Door 
Lock Switch

 

X

 

X

 

Splic

Splic

Cut the 
Existing 
Lock Wire

To Door
Lock 

To Slave Door 
Lock switches 

Green/ white 

Green/ red 

 

Cut the Existing 
Unlock Wire

Blue/ white 

Blue/ red   

+ 12V 

Green/ yellow 

Blue/ yellow 

 

 

 

VACUUM OPREATE DOOR LOCKING SYSTEM

Green/ white 

Blue/ red 

Green/ red

Blue/ white

Blue/ yellow 

Green/ yellow 

+12V

X

Cut

Compressor 

Door Switch 

 

MEGA 2550 INSTALL 

6

Summary of Contents for MEGA 2550

Page 1: ...MEGA 2550 2 WAY LCD PAGER ALARM Installation Manual MEGATRONIX CHATSWORTH CA USA MEGA 2550 INSTALL 1...

Page 2: ...MEGA 2550 INSTALL 2...

Page 3: ...cle Frame 2 White Wire Parking Light Relay Output 1 Red White Wire Parking Light Relay Power Input 3A Fuse 10A Fuse H8 13 PIN MINI CONNECTOR WIRE HARNESS 4 Green Wire Zone 3 Negative Door Pin Trigger...

Page 4: ...evice It is a transistorized low current output and should only be connected to the low current positive output from the vehicle s horn switch H1 5 Red wire System Power 12V Constant The RED wire supp...

Page 5: ...key switch to the RED wire pin 30 of the relay and connect the starter wire to the WHITE wire pin 87a of the relay e Connect the ORANGE Wire from the control module to the ORANGE wire pin 86 of the r...

Page 6: ...r the same duration as the siren H4 6 PIN DOOR LOCK HARNESS Blue White Wire 30 Door Unlock Relay Blue Red Wire 87a Door Unlock Relay Blue Yellow Wire 87 Door Unlock Relay Green Red Wire 87a Door Lock...

Page 7: ...e H4 6 Pin Door Lock Wire Harness Blue Red Blue Yellow 12V OEM Door Lock Relay 2 STEP DOOR UNLOCK WIRE CONNECTION FOR POSITIVE SWITCHED DOOR LOCKS Cut Existing Unlock X Lock Unlock OEM Door Master Loc...

Page 8: ...1 Turn the Ignition switch ON OFF 3 TIMES and stay in the OFF position 2 Push the Valet switch 4 times and hold it on the 4th push until two chirps with a long chirp is heard Then release the valet sw...

Page 9: ...and 2 minutes Exit Turn Ignition to the ON position or leave it for 15 seconds 3 long chirps will confirm exit Channel 3 4 Timer Control Output Programming 1 Turn the Ignition switch ON OFF 3 TIMES a...

Page 10: ...itch to the OFF position If the new password code were accepted the unit would report the newly entered code by flashing the LED first indicating the first digit code has been memorized pause and then...

Page 11: ...se the transmitter button again 2 LED flash 2 siren horn chirps to indicate you are in shock sensor connected to H2 4 pin plug test mode 1 Activate the warn away first stage optional sensor The system...