Unvented Hot Water Cylinder
8
Table 2 - Dimensions
PRODUCT SPECIFICA
TION (1)
*
A SECOND ELEMENT KIT CAN BE PURCHASED, KIT NO 95970554
SIZE
TYPE
INDIRECT
DIMENSIONS (mm)
145L
170L
210L
250L
300L
125L
SB
SB
SB
SB
SB
SB
A
B
C
D
E
316
316
316
316
316
316
355
355
355
355
355
355
794
895
1020
1095
1323
1574
1102
1229
1384
1486
1738
2053
709
810
934
1011
1238
1526
F
N/A
N/A
N/A
*
*
*
170
210
250
300
125
145
1.05
1.18
1.20
1.42
1.61
1.69
383.3
430.7
438.0
518.3
587.7
616.9
STANDING HEAT LOSS
NOMINAL
CAPACITY
(LITRES)
PER DAY
(kWh/24h)
PER YEAR
(kWh/24h)
Table 1 - Standing Heat-loss
Specifications and Dimensions
Outline Specifications
Maximum mains water supply pressure (to 3 bar pressure reducing valve)
1.6 MPa (16 bar)
Operating pressure (pressure reducing valve set pressure – non adjustable)
0.3 MPa (3 bar)
Expansion relief valve set pressure
0.8 MPa (8 bar)
Temperature / pressure relief valve set temp / pressure
90ºC / 1MPa (10 bar)
Immersion heater rating (a.c. supply only)
3kW @ 240V 50Hz
2.8kW
@
230V
50Hz
Outer casing:
White textured plastic coated corrosion resistant steel
Water container:
Duplex stainless steel. 100% pressure tested to 1.5 MPa (15 bar).
Thermal insulation:
CFC/HCFC free fire retardant expanded polyurethane foam with zero ozone depletion potential. It has a Global Warming
Potential (GWP) of 3.1. Nominal thickness 60mm.
Pipe connections:
All connections accept 22mm outside diameter pipe – compression nuts and olives supplied. Thread rate is
3
/
4
” BSP male
parallel to accept standard
3
/
4
” BSP female fittings if required.
Safety features:
Manually resettable thermal cut-out on heating element
Manually resettable thermal cut-out for primary heating. Is wired in conjunction with 2-port motorised valve supplied
Factory fitted temperature / pressure relief valve
The pace of product development is such that we reserve the right to change product specifications
without notice. We do, however, strive to ensure that all information in this product guide is accurate at the time of
publication.
Summary of Contents for Eco SystemReady
Page 11: ...Unvented Hot Water Cylinder 11 PRODUCT SPECIFICATION 1 PRODUCT SPECIFICATION 1 NOTES...
Page 26: ...Unvented Hot Water Cylinder 26 NOTES INSTALLATION AND COMMISSIONING INSTRUCTIONS 2...
Page 34: ...Unvented Hot Water Cylinder 34 MAINTENANCE AND SERVICING 3...
Page 35: ...Unvented Hot Water Cylinder 35 MAINTENANCE AND SERVICING 3...
Page 37: ...Unvented Hot Water Cylinder 37 User Instructions Guarantee Customer Service USER GUIDE 4...
Page 43: ...Unvented Hot Water Cylinder 43 USER GUIDE 4 Notes...