Megacon COMPALARM E Instruction Manual Download Page 8

 

Compalarm E 

Manuale istruzioni / Instruction manual 

IM690-IU v0.1 

pag. 8 / 12

 

M08 – CASELLE ALLARMI 
(An n=1..16)

 

Default 

Range 

14.01 

Testo allarme 

Bianco 

Nero-Grigio-

Bianco-Rosso-

Rosso scuro-

Arancio-Giallo-

Verde-Verde 

scuro-Azzurro-

Blu-Viola- 

Viola scuro 

14.02

 

Sfondo allarme 

Rosso 

14.03

 

Testo non in allarme 

Nero 

14.04

 

Sfondo non in allarme 

Grigio 

14.05

 

Numero di linee 

1..3 

 

M09 – CASELLE GRUPPI 
(GROUPn n=1..16)

 

Default 

Range 

15.01 

Testo allarme 

Bianco 

Nero-Grigio-

Bianco-Rosso-

Rosso scuro-

Arancio-Giallo-

Verde-Verde 

scuro-Azzurro-

Blu-Viola- 

Viola scuro 

15.02

 

Sfondo allarme 

Rosso 

15.03

 

Testo non in allarme 

Nero 

15.04

 

Sfondo non in allarme 

Grigio 

15.05

 

Numero di linee 

1..3 

 

M10 – MODIFICA TESTI ALLARMI 
(An n=1..16)

 

Default 

Range 

16.01 

Numero allarme 

1..16 

(testo – 4 char) 

16.02

 

Linea 1 allarme 

An 

(testo – 12 char)

 

16.03

 

Linea 2 allarme

 

An 

(testo – 12 char)

 

16.04

 

Linea 3 allarme

 

An 

(testo – 12 char)

 

16.05

 

Linea 1 aiuto

 

HELP 

(testo – 12 char)

 

16.06 

Linea 2 aiuto

 

HELP 

(testo – 12 char)

 

16.07 

Linea 3 aiuto

 

HELP 

(testo – 12 char) 

 

M11 – MODIFICA TESTI GRUPPI 
(GROUPn n=1..16)

 

Default 

Range 

17.01 

Numero allarme 

1..16 

(testo – 4 char) 

17.02

 

Linea 1 

An 

(testo – 12 char)

 

17.03

 

Linea 2

 

An 

(testo – 12 char) 

17.04

 

Linea 3

 

An 

(testo – 12 char)

 

 

M12 – OPZIONI LOG 

 

Default 

Range 

P17.01 

Modo registrazione 

STOP 

STOP - LOOP 

P17.02

 

Allarme 

ON 

OFF - ON 

P17.03

 

ACK evento 

ON 

OFF - ON 

P17.04

 

RESET evento 

ON 

OFF - ON 

P17.01

 – Quando la memoria è piena si può fermare la registrazione (modo 

STOP) oppure continuare sovrascrivendo i dati più vecchi (modo LOOP). 

P17.02

 – Se impostato ad ON, tutti gli allarmi verranno memorizzati.  

P17.03

 – Se impostato ad ON, tutti gli eventi di ack verranno memorizzati. 

P17.04

 – Se impostato ad ON, tutti gli eventi di reset verranno memorizzati. 

 

M13 – OPZIONI TEST 

 

Default 

Range 

P18.01 

Buzzer 

OFF 

OFF - ON 

P18.02

 

Uscite relè 

OFF 

OFF - ON 

P18.03

 

Primo-fuori 

OFF 

OFF - ON 

P18.01

 – Durante il test sequenza, viene attivata la segnalazione acustica. 

P18.02

 – Durante il test sequenza, vengono attivate le uscite relè. 

P18.03

 – Durante il test sequenza, viene attivato il riconoscimento di primo-

fuori. 

 
 
 
 
 
 
 

M08 – ALARM WINDOWS 
(An n=1..16)

 

Default 

Range 

14.01 

Alarm text   

White 

Black-Gray-

White-Red-Dark 

Red-Orange-

Yellow-Green-

Dark Green-

Sky Blue-Blue-

Purple- 

Dark Purple 

14.02

 

Background alarm 

Red 

14.03

 

No alarm text 

Black 

14.04

 

Background no alarm 

Gray 

14.05

 

Number of text lines 

1..3 

 

M09 – GROUP WINDOWS 
(GROUPn n=1..16)

 

Default 

Range 

15.01 

Alarm text   

White 

Black-Gray-

White-Red-Dark 

Red-Orange-

Yellow-Green-

Dark Green-

Sky Blue-Blue-

Purple- 

Dark Purple 

15.02

 

Background alarm 

Red 

15.03

 

No alarm text 

Black 

15.04

 

Background no alarm 

Gray 

15.05

 

Number of text lines 

1..3 

 

M10 – EDITING ALARM TEXT 
(An n=1..16)

 

Default 

Range 

16.01 

Alarm number 

1..16 

(text – 4 char) 

16.02

 

Alarm line 1 

An 

(text – 12 char)

 

16.03

 

Alarm line 2 

An 

(text – 12 char)

 

16.04

 

Alarm line 3 

An 

(text – 12 char)

 

16.05

 

Help line 1 

HELP 

(text – 12 char)

 

16.06 

Help line 2 

HELP 

(text – 12 char)

 

16.07 

Help line 3 

HELP 

(text – 12 char) 

 

M11 – EDITING GROUP TEXT 
(GROUPn n=1..16)

 

Default 

Range 

17.01 

Alarm number 

1..16 

(text – 4 char) 

17.02

 

Group line 1 

An 

(text – 12 char)

 

17.03

 

Group line 2 

An 

(text – 12 char)

 

17.04

 

Group line3  

An 

(text – 12 char)

 

 

M12 – LOG OPTIONS 

 

Default 

Range 

P17.01 

Recording mode 

STOP 

STOP - LOOP 

P17.02

 

Alarm occurred 

ON 

OFF - ON 

P17.03

 

ACK event 

ON 

OFF - ON 

P17.04

 

RESET event 

ON 

OFF - ON 

P17.01

 – When the memory is full, the user can choose to stop the recording 

(STOP mode) or to continue overwriting the oldest records (LOOP mode). 

P17.02

 – If set ON, all alarms will be stored.  

P17.03

 – If set ON, all acknowledge event pushbutton will be stored. 

P17.04

 – If set ON, all reset event pushbutton will be stored. 

 
 

M13 – TEST OPTIONS 

 

Default 

Range 

P18.01 

Buzzer 

OFF 

OFF - ON 

P18.02

 

Output relays 

OFF 

OFF - ON 

P18.03

 

First-out 

OFF 

OFF - ON 

P18.01

 – During the functional test, the horn circuit will operate. 

P18.02

 – During the functional test, the output realys will operate. 

P18.03

 – During the functional test, the first-up alarm will operate. 

 
 
 
 
 
 
 

Summary of Contents for COMPALARM E

Page 1: ...E Manuale istruzioni Instruction manual IM690 IU v0 1 pag 1 12 MANUALE OPERATIVO INSTRUCTION MANUAL IM690 IU M v0 1 COMPALARM E Annunciatore d allarme programmabile COMPALARM E Programmable alarm ann...

Page 2: ...Serve per lo scorrimento a sinistra delle pagine per resettare l allarme quando l ingresso tornato alla condizione normale riposo Tasto SELECT Server per lo scorrimento a destra delle pagine per sele...

Page 3: ...display page with alarm windows visualization Example of display page with alarm icons visualization Event log Display caselle d allarme Notifiche allarmi Tasto SILENCE Tasto ACK Tasto RESET Display c...

Page 4: ...rmi OFF OFF ON 02 01 Ripristina tutte le impostazioni ai valori di default di fabbrica 02 02 Ripristina solo le impostazioni di setup ai valori di fabbrica 02 03 Azzera la lista eventi 02 04 Ripristin...

Page 5: ...an rate 06 05 Indirizzo seriale del protocollo di comunicazione 06 06 Velocit di trasmissione della porta di comunicazione 06 07 Numero bit di stop 06 08 Formato dati 06 09 Tempo minimo di ritardo nel...

Page 6: ...Impostare il numero del gruppo utilizzando la voce di menu 09 03 GROUP Uscita abbinata allo stato del gruppo associato Impostare il numero del gruppo utilizzando la voce di menu 09 04 M02 ETHERNET Mea...

Page 7: ...16 ON OFF ON 12 01 Se impostato ad ON il canale di ingresso n abilitato al riconoscimento dell allarme di primo fuori M07 IMPOSTAZIONE GRUPPI Default Range 13 01 ALARMn n 1 16 Group 1 Group 1 16 13 01...

Page 8: ...equenza viene attivata la segnalazione acustica P18 02 Durante il test sequenza vengono attivate le uscite rel P18 03 Durante il test sequenza viene attivato il riconoscimento di primo fuori M08 ALARM...

Page 9: ...1 9 INGRESSI 10 16 INPUTS 10 16 ETHERNET B A COM1 COM2 B A SIRENA HORN FIRST OUT PRIMO FUORI C C B LOAD N O RELAY1 RELAY2 LOAD N C L N A VISUALIZZAZIONE VISUAL DISPLAY CONNESSIONE RS485 RS485 CONNECT...

Page 10: ...alarm E Manuale istruzioni Instruction manual IM690 IU v0 1 pag 10 12 Disposizione morsetti Dimensioni meccaniche e foratura pannello mm Terminals position Mechanical dimensions and front panel cutout...

Page 11: ...peratura d impiego 0 60 C Temperatura di stoccaggio 10 70 C Umidit relativa 5 95 Conformit Conformit a norme EN 50081 2 1992 EN 55022 CLASSE B CISPR 22 EN 50082 1 1992 EN 61000 6 2 EN61010 2 Technical...

Page 12: ...Instruction manual IM690 IU v0 1 pag 12 12 Per ulteriori informazioni contattare Megacon AB Ranhammarsv gen 20 S 168 67 Bromma Sweden Phone 46 0 8 402 42 50 E Mail sales megacon se www megacon se For...

Reviews: