Mega Lite Deco Drive IP User Manual Download Page 5

5

 

Control Board

 

Power

 

(Off)

 

Power

 

(On)

 

Unlock

 

(Yes)

 

Unlock

 

(No)

 

W

-

DMX 

 

Power Off

 

Linking

 

Waiting

 

W

-

DMX

 

No Link

 

DMX Address

 

Press 

Enter

 to select the output Port use the 

Up/Down 

to select from 01 to 04

 

 

1 CH

 

2 CH

 

3 CH

 

Single Color Fixture

 

Variable White Color Fixture

 

3 Color Fixture, Red, Green, Blue

 

Wireless DMX

 

This function allows you to connect signal to the fixture using a wireless DMX connection.  A Wireless Solution Transmit-

ter is required for this function to operate.

 

Menu

 

Enter

 

Up

 

Down

 

CONTROL BOARD

 

Mega Lite 

 

Deco Drive IP

 

 

DMX 

 

4 CH

 

7 CH

 

4 Color Fixture, Red, Green, Blue, White

 

4 Color Fixture, Dimmer, Red, Green, Blue, White, Strobe, Macro

 

WDMX Set

 

DMX Port 

 

04

 

 

P04 Mode

 

(07)

 

Press 

Enter

 to select the Channel Mode use the 

Up/Down 

to select from options 

below

 

 

P04 ADDR

 

(001)

 

Press 

Enter

 to select the DMX Start Channel use the 

Up/Down 

to select output 

port DMX Start Channel.  (Note if you want multiple output ports operating in the 

same way just use the same Mode and Start Channel  for what ever port you want 

to work the same )

 

Press 

Enter

 and use the 

Up/Down 

buttons to engage or disengage 

this function

 

Press 

Enter

 and use the 

Up/Down 

buttons to open communication 

Mode Yes to open No to leave closed.  Function Button on the wire-

less transmitter must be engaged for the communication to be sent

 

W

-

DMX 

 

Status

 

Display Status of Wireless DMX connection Status.  Display should 

read (Linked) for proper Wireless connection

 

W

-

DMX

 

Linked

 

Summary of Contents for Deco Drive IP

Page 1: ...mation 2 What Is Included 2 Specifications 3 Main Power Connection 4 DMX 512 Connection 4 Output Connection 4 Control Board 5 DMX Profile 7 Size Weight 8 Cleaning Maintenance 9 Parts List 9 Warranty 1...

Page 2: ...e Protection Against Electrical Dangers 1 Disconnect power before servicing 2 For connection to main power supply proceed to page 4 3 This unit must be earthed electronically grounded 4 The Unit must...

Page 3: ...ection CON COL DC5 Electrical Specifications Power Input 90 264VAC 50 60 Hz Output Ports 4 Power Per Output 100W Total Max Power 580W Operating Power Consumption 3 29 Amps 384 Watts Ballast Electronic...

Page 4: ...220V L L R Output Connection Deco Driver IP is designed to be used as a driver for Constant Voltage lighting fixtures There are many fixtures a Deco Driver can control Each of the 4 output can be ind...

Page 5: ...Blue White Strobe Macro WDMX Set DMX Port 04 P04 Mode 07 Press Enter to select the Channel Mode use the Up Down to select from options below P04 ADDR 001 Press Enter to select the DMX Start Channel us...

Page 6: ...use Red Only For Variable White fixtures use Red and Blue For R G B fixtures use Red Green Blue For RGBW fixtures use Red Green Blue White Blue 001 255 White 001 255 Dimmer Speed Fast or Smooth Setti...

Page 7: ...Description Value Init 1 LED Color Red LED Intensity all outputs 0 255 255 2 LED Color Green LED Intensity all outputs 0 255 255 3 LED Color Blue LED Intensity all outputs 0 255 255 4 LED Color White...

Page 8: ...8 Size Weight Fixture Size 13 25 X 8 5 X 4 12 Fixture Packaged 14 75 X 12 X 6 75 Net Weight 8 8lb Gross Weight 9 8lb 13 25 4 12 6 9 5 With Power Cable 2 5 11 87...

Page 9: ...ls decoration material 4 Installation location must have adequate air flow 5 M10 treaded mount is provided on the side of the fixture for clamp mount When rigging a unit it is very important that you...

Page 10: ...10...

Page 11: ...answer any question should you encounter a prob lem Please visit our website for any other related technical documents For service related issue please contact our service dept Monday Friday 9am to 6p...