9
Cleaning and maintenance
Installation Maintenance:
The operator has to make sure that the unit is operating safely and has the installations and electron-
ics checked by an expert every 2 years.
The following points have to be considered during the inspection:
1)
All screws used for installing the device or part of the device have to be tightly connected and must not be corroded.
2)
There must not be any deformations on the housing, fixation and installation spots (ceiling, suspension, trussing).
3)
Mechanically moved parts like axles, fans and other must not show any traces of wearing and must not rotate with unbal-
ances.
4)
The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments. Further
instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems
have to be removed.
Disconnect from mains before starting maintenance operation!
Caution Danger to life!
We recommend a frequent cleaning of the device. Please use a moist, lint free cloth. Never use alcohol or solvents!
1)
The objective lens will require periodic cleaning on usage and environment. Environment with foggers will require more peri-
odic cleaning as fog fluid tends to build up residues, reducing the light output.
2)
The cooling
-
fans should be cleaned monthly. DO NOT blow high pressure air into fans as incorrect rotation can damage the
fans operation.
3)
The gobos, dichroic color filters and internal lenses may be cleaned with soft brush using soapy water.
Note:
There is no serviceable parts inside the device except for the fans and the fuse. Maintenance and service operations are
to be carried out by authorized dealers.
Replacing the fuse:
Only replace the fuse with the same type and rating.
Replacing the power cable:
If the power cable of this device becomes damaged, it has to be replaced by authorized dealers only
In order to avoid hazards.
Should you have further questions , please contact your dealer.
Parts List
P
-
1100DISC
Display Card
P
-
1100DMXC
DMX Card
P
-
1100FH
Fuse Holder
P
-
1100LEDb
Blue LED
P
-
1100C
Quick Release Mount Set
P
-
1100LEDr
Red LED
P
-
1100LF
Large Fan
P
-
1100PCB
Main PCB Card
P
-
1100MS
Motor Sensor
P
-
1100LEDg
Green LED
P
-
1100PB
Pan Band
P
-
1100PM
Pan Motor
P
-
1100PS
Power Switch
P
-
1100PSUP
Power Supply
P
-
1100RF
LED Reflector
P
-
1100PBS
Plastic Body Set
P
-
1100T
Transformer
P
-
1100TB
Tilt Band
P
-
1100TM
Tilt Motor
P
-
1100SF
Small Fan