Check that the unit has not been damaged during transport

 

Protection Against Fire

 

1.

 

Maintain a minimum of 1 foot distance from any type of flame.

 

2.

 

Replace fuse only with the specified type and rating.

 

3.

 

Do Not install the unit to close to a heat source.

 

4.

 

Make sure cable are properly secured away from unit movement.

 

5.

 

Maximum surface operating temperature 80

º.

 

Protection Against Fire

 

1.

 

Disconnect power before servicing.

 

2.

 

For connection to main power supply proceed to page 4.

 

3.

 

This unit must be earthed. (electronically grounded) 

 

4.

 

Do not expose unit to rain or moisture.

 

Protection Against Mechanical Hazards

 

1.

 

Make sure head movement is not blocked.

 

2.

 

Use safety chain when hanging unit

 

3.

 

Unit surface may reach high temperature.  Allow about 5 minutes after lamp has been turned off be-

fore moving.

 

 

3

 

Summary of Contents for Axis LED

Page 1: ......

Page 2: ......

Page 3: ...rom unit movement 5 Maximum surface operating temperature 80 Protection Against Fire 1 Disconnect power before servicing 2 For connection to main power supply proceed to page 4 3 This unit must be ear...

Page 4: ...Maximum surface temperature 80 C Mounting Points 2 pairs of L turn locks Fastening System 2 quick clamp release Electrical Specifications 12 25 13 5 7 9 25 4 75 9 5 10 75 3 5 LED Quantity 54 Red 18 Gr...

Page 5: ...ir cable designed for RS 485 and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or the fixture with another DMX input DMX output 1 Shield Ground 2 Signal 3 Signal C...

Page 6: ...low common safety procedures Rigging requires extensive experience includ ing but not limited to calculating working loads material being used and periodic safety inspections If you lack these qualifi...

Page 7: ...50 151 255 Fan speed from fast to slow Reset hold for 3 secounds No Changes Control 6 Red LED 0 100 Red LED 7 0 255 Green LED 0 100 Green LED 8 0 255 Blue LED 0 100 Blue LED 9 0 255 1 19 210 219 200 2...

Page 8: ...e Pan This function allows you to invert the Pan direction Use the up down keys to select Y to invert pan and N not to invert the pan Press Enter to confirm or Mode exit and return to the mail menu Re...

Page 9: ...e periodic cleaning on usage and environment Environment with foggers will require more peri odic cleaning as fog fluid tends to build up residues reducing the light output 2 The cooling fans should b...

Page 10: ...Mega Lite 5718 Kenwick St San Antonio TX 78238 Ph 210 684 2600 Fax 210 855 6279 www mega lite com info mega lite com...

Reviews: