background image

 

MEFE—Mitchell Engineering Food Equipment Pty Ltd

 

23 Storie Street Clontarf QLD 4019 Australia

 

www.mefe.com.au | [email protected]

 

Page 4

 

+617 3283 4536

 

Free AU 1800 669 006

 

 

 

 

 

Fault Check

 

Before fault checking: 

please make sure the installation distance is adequate and correct by referring to the Pre

-

installation instructions.

  

 

 

The LED indicator will light up twice and then stop once after the batteries are installed. To confirm the sensor is work-
ing, place your hand within the sensing range and check that the LED indicators lights once.

 

Problem

 

The faucet has no water flow and there is no LED indicator light when within the sensing range

 

Cause

 

The batteries are not supplying electricity to the sensor.

 

Solution 1

 

Confirm the batteries have been correctly installed. Check that the positive pole is connected to 

“+” 

mark on 

the plastic battery box. Check that the negative pole is connected to 

-

“ 

mark on the plastic battery box. Con-

firm the batteries are the correct size as per this manual and have not been forced.

 

Solution 2

 

If the LED indicator does not light up and power is confirmed, replace the sensor control module.

 

Problem

 

The faucet has no water flow and there is a LED indicator light when within the sensing range

 

Cause 1

 

Inadequate electricity supply.

 

Solution

 

Place hands under the sensing range for >5 seconds. If the LED indicator blinks every 1.5 seconds there is in-
adequate electricity.

 

Cause 2

 

Solenoid valve components are defective.

 

Solution

 

The LED indicator should spark for 2 seconds and then turn off. Place your hands within the sensing range, if 
the LED indicator lights up once but you can not hear the audible 

click

” 

sound from the sole

-

noid valve, 

please check the connections between the sensor control model and solenoid valve. If the connections are 
good, change the solenoid valve components.

 

Problem

 

The faucet has low water flow

 

Cause

 

Low water pressure or water supply stop(s) are partially closed.

 

Solution

 

Refer to installation step 

3

—at this point, increase water pressure and open the water supply stop (s) fully.

 

Problem

 

The faucet has water flow but does not close completely

 

Cause 1

 

The solenoid valve is blocked by debris.

 

Solution

 

Disassemble the solenoid valve and clean it. Flush pipes and ensure water supply is free of debris. Change the 
solenoid valve components if the problem is not solved. 

 

Cause 2

 

Low water pressure.

 

Solution

 

Increase water pressure.

 

Problem

 

The faucet has water flow but will not stop running

 

Cause

 

Please confirm adequate electricity supply and solenoid valve connections. 

 

Solution

 

If the problem persists, check that the sensing range is adequate i.e. installed above the washbasin no less 
than 25cm. Check that the basin surface is not stainless steel or reflective.

 