7. Breakdown analysis and removal Continued

 

7

-

3 Breakdown and removal of single stage rotary sheet vacuum pump

 

Breakdown

 

Reason

 

Solving method

 

Pump can

t reach the stipulated max. 

vacuum   

 

Lubricant oil goes bad

 

Re

-

measure max. vacuum after replacing oil

 

Oil in tank isn

t enough

 

Add oil to the stipulated oil level

 

Oil pipe leaks

 

Replace or reassemble oil pipe

 

Sealing of aspiring pipe is poor

 

Check on the sealing condition of pipe and 

connecting position for getting rid of leakage

 

Air

-

in valve sheet is jammed

 

Check up if the air

-

in valve

s action is flexible

 

Oil sealing leaks

 

Replace the oil sealing

 

Vane is distorted and the slide isn

t smooth

 

Replace vane

 

Worn

-

and

-

torn inside

 

Repair the worn position or re

-

adjust

 

Pump can

t start

 

Insufficient voltage or burned fuse

 

Check on voltage on fuse

 

Pump or motor is jammed

 

Remove fan cover, try to turn the motor with a 

hand, then find out the reason of jamming

 

Pump

s starting current or work current 

is too high  

 

Pump oil is too full or the brand is wrong

 

Check on oil level and brand

 

Lower temperature is causing too high 
viscosity of lubricating oil

 

Replace with oil of lower viscosity. Start after 

preheating oil when environmental temperature 

is lower than 5⁰C

 

Exhaustion filter is blocked

 

Clean or change filter

 

The temperature is too high when pump 

runs 

 

Pump oil is too full or too little

 

Check on and adjust oil level

 

Heat radiation is poor

 

Clean the radiating fins of pump and motor to 

improve the ventilation situation

 

Pump is jammed when running 

 

Running under wrong direction for a long time

 

Correct the turning direction and do an overall 

check

-

up of pump at the same time

 

Friction surface is lacking of oil

 

Dredge oil pipe and check up gap to find out the 

reason of lacking oil

 

Abnormal noise when the pump runs

 

Driving parts are seriously worn or loose

 

Find out the trouble position and repair in time

 

Air vent smokes or vents oil drop 

 

Pump oil is too full

 

Discharge redundant oil

 

The installation position of exhaust filter isn

correct or the material breaks 

 

Reassemble or change the exhaust filter

 

Exhaust filter is blocked

 

Clean or change filter

 

Summary of Contents for CAT 370 550

Page 1: ...gineering Food Equipment Pty Ltd 23 Storie Street Clontarf QLD 4019 Australia www mefe com au info mefe com au Page 1 617 3283 4536 Free AU 1800 669 006 Operation Manual Vacuum Packing Machine CAT 370...

Page 2: ...e com au Page 2 617 3283 4536 Free AU 1800 669 006 Contents 1 Uses and Characteristics 3 2 Model and Technical Parameters 3 3 Appearance and Control Panel Layout 3 4 4 Use Preparation 4 5 Operation Pr...

Page 3: ...he food s storage period Characteristics 1 This machine is easily used From pressing the cover of the machine to draw out air heating the sealing printing the label cooling filling with gas and openin...

Page 4: ...nce it is has reached the set sealing time The atmosphere will enter into the vacuum room through the solenoid valve then the cover of the machine will open automatically The whole procedure is finish...

Page 5: ...ically 6 The Vacuum packer will form an airtight seal and draw air for the entered in time 7 Once the time for the air drawing has ended the machine will seal the packaging for the entered in time Aft...

Page 6: ...g Replace Pipe joint is loose Tighten Small gas cell leaks Seal ring of vacuum room is broken or scraped Replace Upper plane of vacuum room isn t flat Properly adjust Solenoid valve leaks for instance...

Page 7: ...then find out the reason of jamming Pump s starting current or work current is too high Pump oil is too full or the brand is wrong Check on oil level and brand Lower temperature is causing too high v...

Page 8: ...Solenoid valve of small gas cell doesn t act See Table 7 2 Heat seal strip is jammed and can t move The lines at the sealing of the package is not even Electrothermal belt is loose Tighten belt The s...

Page 9: ...Sealing Transformer 1 8 Working Transformer 1 9 Relay 1 10 Breaker 1 11 Inflatable Solenoid Valve 1 12 Power Switch 1 13 Inflatable Controller 1 14 Fan 1 15 Vacuum Cover 1 9 Parts Breakdown Part numbe...

Reviews: