background image

Meet PAT™

 | Products and Things Pty Ltd | 

meetpat.com.au

 | Level 1, 419 Townsend Street, Albury, NSW, 2640, Australia

Phone: (02) 60217813, +61260217813 Email: [email protected]

Meet PAT™

 | Meet PAT Limited NZ | 

meetpat.co.nz 

| 12 Bethlehem Road, Bethlehem, Tauranga, 3100

Page 7

MP-TO-01 - “The one” - 

 

edge Plumbing - Installation 

50mm

*min clearance 
from the wall
to the unit

*An external water
trap is required for 
the top plumbing 
position.
Not supplied with
the unit.

*The plumbing 

can be configured

to exit the unit
from two possible
locations.

190mm

475mm

Attaching to an existing structure

Embedding in concrete

Installation Kit - 

Not included

Base plate - sizing

*Unit can be fixed to any flooring structure 

Meetpat recommends 

4 x M12 Countersunk 

Stainless Steel fasteners. Not included.

Length and type of the fastener to be confirmed 
by installer.

*Unit can be embedded into a new concrete slab. 
Meetpat recommends a minimum slab size of
550W x 550L x 200mmD

This may need to be increased or reinforced 

depending on sub surface conditions.

Confirm with installer for suitable slab site.

Please contact Meetpat for a installation kit.

Mounting Plate

4 x M12 Stainless 

Steel bolts

150mm

210mm

200mm

260mm

*Two holes are required 
to be cut in the side of 
the unit for the plumbing.

25mm

45mm

Summary of Contents for MP-TO-01

Page 1: ...ownsend Street Albury NSW 2640 Australia Phone 02 60217813 61260217813 Email sales meetpat com au Meet PAT Meet PAT Limited NZ meetpat co nz 12 Bethlehem Road Bethlehem Tauranga 3100 THE one permanent...

Page 2: ...not use if any leaks are prevalent Units can be heavy to install use the appropriate number of people and equipment Ensure the units are regularly cleaned and serviced If applicable ensure the water...

Page 3: ...hin the units The units are mounted to a 8mm powder coated steel bollard Graphics panels are made from clear high impact spray paint uv and scratch resistant polycarbonate sheet The graphics are back...

Page 4: ...kpa operating pressure Filter 5 micron carbon filter Flow Rate 5L per minute pressure dependent Power None Flow Meter Digital in litres Minimum Working Temp 1 C Water Supply Connection 1 2 inch supply...

Page 5: ...many different positioning options These options can allow you to install a unit very cost effectively with minimal infrastructure changes Water supply The unit can be connected to any existing potabl...

Page 6: ...te slab using the mounting bracket Units can bolt directly onto existing ooring structure Connect through to existing connections on the other side of walls Connect waste water into existing drainage...

Page 7: ...5mm Attaching to an existing structure Embedding in concrete Installation Kit Not included Base plate sizing Unit can be xed to any ooring structure Meetpat recommends 4 x M12 Countersunk Stainless St...

Page 8: ...luded Length and type of the fastener to be con rmed by installer Unit can be embedded into a new concrete slab Meetpat recommends a minimum slab size of 550W x 550L x 200mmD This may need to be incre...

Page 9: ...m slab size of 550W x 550L x 200mmD This may need to be increased or reinforced depending on sub surface conditions Con rm with installer for suitable slab site Please contact Meetpat for a installati...

Page 10: ...pat com au Meet PAT Meet PAT Limited NZ meetpat co nz 12 Bethlehem Road Bethlehem Tauranga 3100 Panel replacement 3mm Allen Key Screws x 3 Clockwise to loosen 1 2 3 3mm Allen Key Screws x 4 Clockwise...

Page 11: ...ed NZ meetpat co nz 12 Bethlehem Road Bethlehem Tauranga 3100 Panel replacement 8mm Allen Key Screws x 1 Anti Clockwise to loosen 7 8 9 Putting it back together All nished and need to put the unit bac...

Page 12: ...unit to a pressurized water source and check for any leaks If a leak is found turn off the water supply and check connections Disconnect water supply Disconnect or turn off the water supply De pressu...

Page 13: ...y the total liter count up 3000lt Attention 1 Do not spray water into or around the ow meter 2 Be careful to not damage the wires when removing the ow meter 3 For replacement parts and troubleshooting...

Page 14: ...ff bracket 2 4mm Allen Key Screws x 4 Anti Clockwise to loosen Only portable models will have a bracket 4 x 2 1 I look like this Record ow meter data If still displayed record the ow meter data Once t...

Page 15: ...to change without notice This technical sheet is copyright and owned by Meet PAT Products and Things Pty Ltd as a trustee for Meet Pat Unit Trust ABN 42634465637 All rights are reserved All products...

Reviews: