TECHNICAL DATA

MP-DF-01-K 

MP-DF-01 

KIDS

REGUALAR

Mounting Options

1. Fixed at base
2. Edge mounted 

Indoor/Outdoor

Suitable for both indoor and outdoor applications.

Tapware/Push Buttons

316 stainless steel Easy-press stainless steel buttons.

Versatile

PAT permanent can mount over the existing tap or outlet. Optional water 
outlet can be included the base of the unit accessible via security tap (key) 
on side of unit. 

Chassis

Aluminium and galvanised mild steel

Graphics Panels

Polycarbonate. Custom printing supplied as standard.

Base Bollard

Powder coated mild steel. M10 Screws. Plate size: 280 x 220mm

Nozzle

316 stainless steel

Water Pressure

Max. 600kpa operating pressure

Filter

5 micron carbon filter

Flow Rate

5L per minute (pressure dependent)

Power

None

Flow Meter

Digital in litres

Minimum Working Temp

1˚C

Water Supply Connection

1/2” inch supply line with 1/2” inch male compression fitting

Drainage

50mm PVC preferred (drainage can be customised based on location. 

Warranty

3 Year (refer to Meet PAT warranty documentation for details)

Meet PAT™ products must be installed in accordance with the provisions of AS/NZS3500 and any relevant local regulations. Installations not complying with AS/
NZS3500 may void the product and performance warranty provisions. All information and images contained in the document are ©  Meet PAT™  - Products and 
Things Pty Ltd (as a trustee for Meet Pat Unit Trust) or their respective owners. They are not be used without consent from Meet PAT™. As improvements in the 

design and performance of Meet PAT products are continuous, specifications may be subject to change without notice. This technical sheet is copyright and 

owned by Meet PAT™  - Products and Things Pty Ltd (as a trustee for Meet Pat Unit Trust) ABN 42634465637. All rights are reserved. 

500mm

670mm

100mm

500mm

100mm

850mm

Summary of Contents for MP-DF-01

Page 1: ...Level 1 419 Townsend Street Albury NSW 2640 Australia Phone 02 60217813 61260217813 Email sales meetpat com au Meet PAT Meet PAT Limited NZ meetpat co nz 12 Bethlehem Road Bethlehem Tauranga 3100 perm...

Page 2: ...not use if any leaks are prevalent Units can be heavy to install use the appropriate number of people and equipment Ensure the units are regularly cleaned and serviced If applicable ensure the water...

Page 3: ...steel bollard Graphics panels are made from clear high impact spray paint uv and scratch resistant polycarbonate sheet The graphics are back printed to prevent scratching on the front face and can be...

Page 4: ...r minute pressure dependent Power None Flow Meter Digital in litres Minimum Working Temp 1 C Water Supply Connection 1 2 inch supply line with 1 2 inch male compression fitting Drainage 50mm PVC prefe...

Page 5: ...many different positioning options These options can allow you to install a unit very cost effectively with minimal infrastructure changes Water supply The unit can be connected to any existing potabl...

Page 6: ...te slab using the mounting bracket Units can bolt directly onto existing ooring structure Connect through to existing connections on the other side of walls Connect waste water into existing drainage...

Page 7: ...included Base plate sizing Unit can be xed to any ooring structure Meetpat recommends 4 x M12 Countersunk Stainless Steel fasteners Not included Length and type of the fastener to be con rmed by insta...

Page 8: ...xed to any ooring structure Meetpat recommends 4 x M12 Countersunk Stainless Steel fasteners Not included Length and type of the fastener to be con rmed by installer Unit can be embedded into a new c...

Page 9: ...f 550W x 550L x 200mmD This may need to be increased or reinforced depending on sub surface conditions Con rm with installer for suitable slab site Please contact Meetpat for a installation kit Mounti...

Page 10: ...Bethlehem Road Bethlehem Tauranga 3100 Panel replacement 3mm Allen Key Screws x 2 Clockwise to loosen 1 2 3 4 Putting it back together All nished and need to put the unit back together Follow the ste...

Page 11: ...unit to a pressurized water source and check for any leaks If a leak is found turn off the water supply and check connections Disconnect water supply Disconnect or turn off the water supply De pressu...

Page 12: ...y the total liter count up 3000lt Attention 1 Do not spray water into or around the ow meter 2 Be careful to not damage the wires when removing the ow meter 3 For replacement parts and troubleshooting...

Page 13: ...ff bracket 2 4mm Allen Key Screws x 4 Anti Clockwise to loosen Only portable models will have a bracket 4 x 2 1 I look like this Record ow meter data If still displayed record the ow meter data Once t...

Page 14: ...to change without notice This technical sheet is copyright and owned by Meet PAT Products and Things Pty Ltd as a trustee for Meet Pat Unit Trust ABN 42634465637 All rights are reserved All products...

Reviews: