Meet PAT MP-DF-01 Information Booklet Download Page 13

Page 13

Meet PAT™

 | Products and Things Pty Ltd | 

meetpat.com.au

 | Level 1, 419 Townsend Street, Albury, NSW, 2640, Australia

Phone: (02) 60217813, +61260217813 Email: [email protected]

Meet PAT™

 | Meet PAT Limited NZ | 

meetpat.co.nz 

| 12 Bethlehem Road, Bethlehem, Tauranga, 3100

flow meter - battery change

3

* Permanent model - flow 

meter lifts off bracket

2

4mm Allen Key

Screws

x 4

Anti

Clockwise 

to loosen

* Only portable models 

will have a bracket

4

x 2

1

I look like this

Record flow meter data

If still displayed, record the flow meter data. 

Once the batteries are removed this data can 
be lost.

*Once a panel has been removed.

Locate the flow meter inside the unit

Once batteries are installed

Attach the flow meter back into place.

Check the unit is working by pressing 

the 

display

 button.

* If the display is not working check the 

battery positions and battery 

connections.

Summary of Contents for MP-DF-01

Page 1: ...Level 1 419 Townsend Street Albury NSW 2640 Australia Phone 02 60217813 61260217813 Email sales meetpat com au Meet PAT Meet PAT Limited NZ meetpat co nz 12 Bethlehem Road Bethlehem Tauranga 3100 perm...

Page 2: ...not use if any leaks are prevalent Units can be heavy to install use the appropriate number of people and equipment Ensure the units are regularly cleaned and serviced If applicable ensure the water...

Page 3: ...steel bollard Graphics panels are made from clear high impact spray paint uv and scratch resistant polycarbonate sheet The graphics are back printed to prevent scratching on the front face and can be...

Page 4: ...r minute pressure dependent Power None Flow Meter Digital in litres Minimum Working Temp 1 C Water Supply Connection 1 2 inch supply line with 1 2 inch male compression fitting Drainage 50mm PVC prefe...

Page 5: ...many different positioning options These options can allow you to install a unit very cost effectively with minimal infrastructure changes Water supply The unit can be connected to any existing potabl...

Page 6: ...te slab using the mounting bracket Units can bolt directly onto existing ooring structure Connect through to existing connections on the other side of walls Connect waste water into existing drainage...

Page 7: ...included Base plate sizing Unit can be xed to any ooring structure Meetpat recommends 4 x M12 Countersunk Stainless Steel fasteners Not included Length and type of the fastener to be con rmed by insta...

Page 8: ...xed to any ooring structure Meetpat recommends 4 x M12 Countersunk Stainless Steel fasteners Not included Length and type of the fastener to be con rmed by installer Unit can be embedded into a new c...

Page 9: ...f 550W x 550L x 200mmD This may need to be increased or reinforced depending on sub surface conditions Con rm with installer for suitable slab site Please contact Meetpat for a installation kit Mounti...

Page 10: ...Bethlehem Road Bethlehem Tauranga 3100 Panel replacement 3mm Allen Key Screws x 2 Clockwise to loosen 1 2 3 4 Putting it back together All nished and need to put the unit back together Follow the ste...

Page 11: ...unit to a pressurized water source and check for any leaks If a leak is found turn off the water supply and check connections Disconnect water supply Disconnect or turn off the water supply De pressu...

Page 12: ...y the total liter count up 3000lt Attention 1 Do not spray water into or around the ow meter 2 Be careful to not damage the wires when removing the ow meter 3 For replacement parts and troubleshooting...

Page 13: ...ff bracket 2 4mm Allen Key Screws x 4 Anti Clockwise to loosen Only portable models will have a bracket 4 x 2 1 I look like this Record ow meter data If still displayed record the ow meter data Once t...

Page 14: ...to change without notice This technical sheet is copyright and owned by Meet PAT Products and Things Pty Ltd as a trustee for Meet Pat Unit Trust ABN 42634465637 All rights are reserved All products...

Reviews: