Cube eye User Manual
23
Using the software
Configuring the settings
1
On the main screen, click
Setup
.
2
Adjust the values in the Setup window.
Integration time(us):
4000 (default)
Modulation Freq.(Mhz):
20 (fixed)
Amplitude Threshold:
0–1000.
(If the amplitude value of each pixel in the IR image is lower than this threshold,
this pixel is invalid. The depth value of this pixel will be changed to zero.)
Soft Distance Offset(mm):
Set the offset distance of depth data.
Min. Depth Range(mm):
Set the minimum depth range.
(A depth value lower than the minimum is zero.)
Max. Depth Range(mm):
Set the Maximum depth range.
(A depth value greater than the maximum is zero.)
※
Set the minimum and maximum values based on the operating environment.
Flip Horizontally:
Set the image to be flipped horizontally.
Flip Vertically:
Set the image to be flipped vertically.
Filter Select:
Apply a smoother filter, segmentation filter, or no filter.
Current Temperature:
This displays the current camera temperature.
Serial Number:
Camera's serial number