Introduction

The Hyperion 971IPS-30 is a powerful, very high voltage pulsed DC ionising bar. It is 
used to control static electric charges in long to extra long-range applications (450-
1500mm). An integral 30kV pulsed DC power supply allows for easy installation on 
extrusion, converting and packaging machinery. Requiring only a 24V DC supply, the 
971IPS-30 removes the need to route high-voltage cabling through the machine. 

In most installations the default settings of the bar will provide exceptional static 
control. The local LED indicators show the operational status of the bar and advises 
when the bar requires cleaning.

Demanding installations can take advantage of the adjustable output of the 971IPS-
30. Using the optional Hyperion BarMaster remote programmer, the frequency and 
balance can be optimised to suit the application. Additionally, the lon Current alarm 
setting can be changed to guarantee the required performance levels on critical 
processes. 

The Hyperion BarMaster remote programmer is available for purchase from the Meech 
network: Visit 

www.meech.com

 to find your nearest Meech office or distributor for 

further product information.

30kV

Summary of Contents for HYPERION 971IPS-30

Page 1: ...1 Hyperion 971IPS 30 Long Range DC Bar Operating Manual Hyperion 971IPS 30 Long Range DC Bar 30kV v1 21...

Page 2: ......

Page 3: ...or visit www meech com Meech Static Eliminators Ltd 26 10 2017 Contents Introduction 3 Unpacking and Inspection 4 Contents 4 Standard Equipment 4 Optional Equipment 4 Features of Hyperion 971IPS 30 5...

Page 4: ......

Page 5: ...ill provide exceptional static control The local LED indicators show the operational status of the bar and advises when the bar requires cleaning Demanding installations can take advantage of the adju...

Page 6: ...ge is evident do not destroy the carton or packing material and immediately notify the carrier of a possible damage claim Shipping claims must be made by the consignee to the delivering carrier Conten...

Page 7: ...30 is powered by 24V DC via a 4 pin M8 Connector Overall look The profile of the Hyperion 971IPS 30 bar is rounded with minimal dirt traps making it useful for cleanroom applications The bar has good...

Page 8: ...before being powered up Emitter Assembly The emitter assembly is a one piece moulding with a 1mm diameter sharp titanium emitter pin The use of titanium pins has a long history at Meech Extremely har...

Page 9: ...ong range performance of the Hyperion 971IPS 30 is excellent some installations can require the use of air assistance to get full control of the static This can either be by increased speeds of decay...

Page 10: ...By default Bar OK 24V Bar needs cleaning or fault detected 0V If required the signal can be inverted to give OK 0V Cleaning Required 24V using a Barmaster Remote Programmer Frequency Indicator A red g...

Page 11: ...erval between cleaning the 971IPS 30 bar features a divider to increase the surface tracking distance between the two rows of high voltage pins It is important to clean this area during cleaning opera...

Page 12: ...exibility of mounting points Integrated air boost Increased performance for demanding applications Installation Mechanical Installation The 971IPS 30 is a medium to long range bar Dependent on the app...

Page 13: ...ion for your installation When installed at short range over a web or sheet the bars must be positioned away from surfaces and rollers as shown in the following diagrams Your Meech distributor will be...

Page 14: ...ech recommend that for certainty the bar is grounded using this post in addition to using a grounded 24V DC supply 971IPS 220V AC 24V DC 0V Power Supply Grounded 0V Grounding using ground post Connect...

Page 15: ...onsibility to check that the 24V power supply they will be using is grounded If it is NOT grounded they must check that grounding it via the ground post on the 971IPS 30 bar will not affect any other...

Page 16: ...0V OK Green LED 0V 0V Dirty Faulty Red LED 0V 0V Dirty Faulty Red LED 24V 0V External Relay Wiring 10k Pull up 24VDC 0V Imax 20mA NO COM NC Relay Power Normally Open Output Matrix Normally Closed Out...

Page 17: ...ly weekly cleaning is sufficient However equipment used in some heavy contamination areas such as gravure printing or where plastic fumes are present may require daily cleaning Equally in a Class 100...

Page 18: ...onged use perhaps after several years the emitter pins may become worn and require replacement Bags of replacement pins are available from Meech and are supplied with a special insertion tool Importan...

Page 19: ...quickly when you first contact Meech 1 Connect to a BarMaster and turn on the equipment 2 A readout will appear on screen and we will require the following information a Bar Code Serial Number b Prod...

Page 20: ...on level with the BarMaster Strobing Red for 2 seconds indicates the BarMaster has been connected Flashing Red on and off indicates more cleaning required Solid Red indicates the ion level has dropped...

Page 21: ...arMaster will not show any change Adjustments to bar settings using BarMaster are not saved after disconnection Power off BarMaster before disconnecting and reconnecting it to a second bar BarMaster d...

Page 22: ...ompanied by a return authorisation number and must be shipped prepaid For prompt service ship the unit to the factory with the return authorisation number shown clearly on the label Be sure that it is...

Page 23: ...21 27VDC Output Voltage 30kV Pulsed DC Electrical Connection 4 Pole M8 Clean Pin Output Signal 24V Output resistance 10k Output Frequency Default Setting 1Hz Adjustable with BarMaster from 0 5 9 5Hz O...

Page 24: ...FINISH TOLERANCE UNLESS OTHERWISE SPECIFIED Machined Work Metric 0 1mm Unmachined Fabrications 1mm Angular 0 30 PROJECTION DIMENSIONS IN MM DO NOT SCALE TITLE DRAWING No REVISION SHEET A3 STATUS CRITI...