14
Output Drive
There are 3 different output drive options which are designed to fulfil the vast majority
of user requirements and to allow easy integration to PLC equipment.
Option 1 - NPN
Transistor-driven switch which presents a pull-up resistor to 24VDC on the alarm pin.
This configuration is the same for both alarm pins (pin-2 and pin-4).
Logic Table
Alarm True = Hi
Start State
Solid Green
Flashing Red
Solid Red
White
Hi
Lo
Hi
Hi
Black
Hi
Lo
Lo
Hi
Alarm True = Lo
Start State
Solid Green
Flashing Red
Solid Red
White
Hi
Hi
Lo
Lo
Black
Hi
Hi
Hi
Lo
Note:
On unit power-up, both alarm pins remain in Hi state for up to 60 seconds
before these are used as alarm pins.
Simplified diagram of NPN output (internally in bar)
2.2kΩ