7

Input/ Output Connections

Ground post

To avoid damage, the 994IML must be grounded. Whether or not the electrical supply 
is grounded (see page 6), it is strongly recommended that the 994IML should be 
grounded using this post.

Power Supply 

2.1mm. Centre positive. 24V. A plug with solder terminals is supplied for the customer’s 

use. 

HT Outputs

Connect the Hydra pinning system to the HT output using the proprietary grey HT 
connector. Ensure the plug is securely fastened using the locking collar. If only one HT 

output is used, the unused output should be blanked off with the plug provided

Remote On/Off

The output of the 994IML can be turned on and off remotely via the socket located on 

the connection panel. A 3.5mm Jack plug, supplied with the unit, connected to volt-free 
contacts will allow the 994IML to be switched on when the contacts are made. 

Relay Contact 

(Volt Free)

 

Note that the unit can also be turned on and off remotely via the Mini Din connection.

Summary of Contents for 994IML

Page 1: ...MODEL 994IML Static Generator Operating Manual...

Page 2: ......

Page 3: ...t Input Signals 8 Using the 994IML 9 Specification 10 CE Approval 10 Maintenance 11 Repairs And Warranty 11 994IML Static Generator Case and Mounting Detail 12 Products shown in this document may be c...

Page 4: ......

Page 5: ...ator has been designed to work with the Hydra In Mould Label pinning system It provides 0 20kV Negative polarity in a lightweight package powered by 24V DC Full local and remote control makes it ideal...

Page 6: ...or packing material and immediately notify the carrier of a possible damage claim Shipping claims must be made by the consignee to the delivering carrier In addition please also notify Meech Internati...

Page 7: ...l 1 Power LED 2 HT On LED 3 Overload LED 4 Rotary Voltage Control Side Panel 1 Ground post 2 On Off Switch 3 24V DC Inlet Centre Positive 4 8 Way Mini DIN Control interface 5 Remote On Off 6 HT Output...

Page 8: ...ed either by using the ground post or by using a grounded 24V supply or both 994IML 220V AC 24V DC 0V Power Supply Grounded 0V Grounding using ground post Mounting Mount the unit using the 5mm keyhole...

Page 9: ...HT output using the proprietary grey HT connector Ensure the plug is securely fastened using the locking collar If only one HT output is used the unused output should be blanked off with the plug prov...

Page 10: ...ded lo Orange Purple Terminal 5 Remote voltage control enabled when grounded lo Yellow Brown Terminal 6 Output current 0 5V 0 500 A Green Green Terminal 7 5V if unit is overloaded Blue Blue Terminal 8...

Page 11: ...led via a 0 5 Volt analogue input Remote monitoring of the output voltage and current is also provided by 0 5V analogue outputs The state of the HT output is reported via a 5V signal In built protecti...

Page 12: ...Supply 24V DC 750 mA Max Output Voltage 0 20kV Negative Max Output Current 500 microAmps CE Approval An EC declaration of conformity for this product exists in respect of the Low Voltage Directive 72...

Page 13: ...your local distributor All products returned to the factory MUST be accompanied by a return authorisation number and must be shipped prepaid For prompt service ship the unit to the factory with the r...

Page 14: ...12 994IML Static Generator Case and Mounting Detail...