4

Unpacking and Inspection 

The Model 977v3 controller was carefully packed at the factory in a container 
designed to protect it from accidental damage. Nevertheless, we recommend careful 
examination of the carton and contents for any damage. If damage is evident, do not 
destroy the carton or packing material and immediately notify the carrier of a possible 
damage claim. Shipping claims must be made by the consignee to the delivering 
carrier.

Summary of Contents for 977v3

Page 1: ...Model 977v3 Operating Manual Pulsed DC Controller...

Page 2: ......

Page 3: ...ce or visit www meech com Meech Static Eliminators Ltd 02 08 17 Contents Introduction 3 Unpacking and Inspection 4 How to use your 977v3 Controller 5 Control Adjustments 6 Alarm 7 LED Displays 7 Meech...

Page 4: ......

Page 5: ...3 Introduction The Meech Model 977v3 controller has been designed to power any of the Meech 900 Series range of DC products...

Page 6: ...tect it from accidental damage Nevertheless we recommend careful examination of the carton and contents for any damage If damage is evident do not destroy the carton or packing material and immediatel...

Page 7: ...of the 977v3 Controller 3 Connect the mains input supply to the Controller and switch ON THIS APPLIANCE MUST BE GROUNDED EARTHED THROUGH THE MAINS ELECTRICAL SUPPLY 4 The attached ioniser will now pro...

Page 8: ...RATE of pulse frequency can be adjusted from 0 5 Hz to 20Hz The lower the frequency RATE the greater the range ie distance over which the ionisation will travel A setting of 5 to 10Hz is recommended f...

Page 9: ...ill be permanently switched off The fault must be removed e g by cleaning of the ionising product and the controller reset by switching the mains supply to it OFF and ON An 8 way DIN socket is provide...

Page 10: ...le for setting the frequency is that the closer the bar is to the object the faster the frequency setting Polarity The polarity adjustment allows the output of the unit to be custom tuned to attack th...

Page 11: ...sed DC Controller was designed to be virtually maintenance free 1 Be sure the unit is switched off and disconnected from the mains supply 2 The outside case may be wiped down with a soft damp cloth 3...

Page 12: ...vent occur disconnect immediately and return equipment to the manufacturer for water damage assessment High voltage electrical equipment should not make contact with water The Model 977v3 Power Supply...

Page 13: ...age on each of the output sockets The reading should be at minimum power 4kV at Max power 8 kV 5 If the controller is found to be functional test each of the attached products independently following...

Page 14: ...epaid For prompt service ship the unit to the factory with the return authorisation number shown clearly on the label Be sure it is well packed in a sturdy carton with shock absorbing material Include...

Page 15: ...and 20Hz Max temperature 60 C Weight 0 5Kg Remote On Off 3 5mm Jack Alarm relay 8 pin DIN connector U style Pin 1 relay normally closed contact Pin 2 ground Pin 3 24V Pin 4 normally open relay contac...

Page 16: ...conformity for this product exists in respect of Low Voltage Directive 72 23 EEC LVD Electromagnetic Compatibility Directive 89 336 EEC EMCD Health and Safety Emission of Ozone Considerably below int...

Page 17: ...15...

Page 18: ......

Page 19: ......

Page 20: ...232 4210 Fax 1 330 564 2005 email info meech com Meech Shavotech 29 2 Kharadi Off Pune Nagar Road On Old Kharadi Mundhwa Road Pune 411014 Maharashtra India Tel 91 0 703 093 8211 91 0 741 000 4817 Fax...

Reviews: