Introduction

In many industrial applications static control is so important that there is a need for a 
device to indicate that the equipment is working correctly.The Meech Model 900vs2 
fulfils this need for Meech AC-powered equipment.  

The 900vs2 is a high voltage sensor that connects to the Meech Model 904 or 905 
Power Unit and monitors the high voltage output, displaying its status via LED’s. 

Description 

The best way to continuously  monitor the operation of AC static eliminators is 
by  verification of the high voltage output of  the Power Unit. This is because static 
elimination equipment that becomes faulty (e.g.when it is dirty or damaged) will draw 
higher current  from the Power Unit  than normal and when the current drawn rises 
above 5mA, the 904 or 905 Power Unit  will automatically shut down. 

(This is a safety feature unique to the Meech Model 904 / 905).The ON/OFF rocker  
switch of the 904 or 905 Power Unit illuminates when the unit is  connected to the 
mains electricity supply. If the high voltage side of the 904 or 905 shuts down as 
indicated above, the rocker switch will remain illuminated (showing  that the mains 
supply is still present) but the static elimination equipment may not be functional.

The 900vs2 has been designed to detect such a condition and display / report this.

Summary of Contents for 900vs2

Page 1: ...Model 900vs2 Operating Manual High Voltage Sensor ...

Page 2: ......

Page 3: ...atents patents applied for and or registered designs and or trade marks For further information please refer to our Head Office or visit www meech com Meech Static Eliminators Ltd 5 01 2012 Contents Introduction 3 Description 3 Connections 4 Operation 4 Technical 5 ...

Page 4: ......

Page 5: ...r Unit This is because static elimination equipment that becomes faulty e g when it is dirty or damaged will draw higher current from the Power Unit than normal and when the current drawn rises above 5mA the 904 or 905 Power Unit will automatically shut down This is a safety feature unique to the Meech Model 904 905 The ON OFF rocker switch of the 904 or 905 Power Unit illuminates when the unit is...

Page 6: ...he unit Operation Under normal operation no system faults the green LED of the 900vs 2 will be continuously illuminated If a fault occurs due to damage and or the ioniser becoming excessively dirty the red LED of the 900vs2 will flash and the green LED will be extinguished If the 904 5 is powered off the 900vs2 will indicate a fault and will be operating from its internal battery e battery will pr...

Page 7: ...5 5 2 1 jack plug socket Connection cable Twin 2m length Dimensions 40 x 120 x 65 mm Battery Rechargeable 9V PP3 120mAh normal Remote indicator connection Internal electrical strip connector max 2A 250VAC Change over relay contacts 250V 2A Internal relay connections Back removed Output relay connections Normally closed Common Normally open ...

Page 8: ...f Conformity for this product exists in respect of the Low Voltage Directive 72 23 EEC LVD Electromagnetic Compatibility Directive 89 336 EEC EMCD Health and Safety Emission of Ozone Considerably below international standard of 0 1ppm ...

Page 9: ...7 ...

Page 10: ...8 ...

Page 11: ...9 ...

Page 12: ... 4210 Fax 1 330 564 2005 email info meech com Meech Static Eliminators Shanghai Co Ltd Room 205 Huana Hotel Office Tower No 1733 Lianhua Road Shanghai 201103 China Tel 86 400 820 0102 Fax 86 400 820 0102 201 email china meech com Meech Elektrostatik SA Kaiserbaracke 66 B 4780 St Vith Belgium Tel 32 8086 2983 Fax 32 8086 2821 email mesa meech com Meech Shavotech Shavo House Survey No 21A 10 B Plot ...

Reviews: