SAFETY INSTRUCTIONS
Read the Operating Instructions carefully before use!
•
The pump must not be modified.
•
The speed of the engine must not be modified.
•
Do not operate indoors.
•
Do not touch the engine during operation or for one hour after operation. Risk of burns.
•
Shut off the engine and allow it to cool before fuelling.
•
The petrol used in the engine is highly flammable and its vapours are explosive. Petrol must be
handled in accordance with current regulations.
•
Make sure that no petrol is spilled during refuelling.
•
Do not fill petrol above the specified level.
•
Smoking is strictly forbidden when refuelling.
•
Open flames, other heat sources and sources of ignition are prohibited in areas used for refuelling.
•
Move the machine at least three metres from the fuelling point before starting it.
•
The machine must not be covered during operation.
•
Exhaust gases contain carbon monoxide. Inhalation of these can lead to death.
•
This equipment must only be used by adults.
•
This equipment must only be used for the purpose for which it is intended.
•
This equipment must not be used if it is damaged.
•
Do not allow children to play with the equipment.
•
Never leave the equipment unattended when in operation to ensure that children or animals do not
come into contact with it.
•
Do not use near flammable liquids or where flammable vapours/gases may be present.
•
Store in a dry place when not in use.
•
Do not expose to chemicals.
•
The pump must not be used for contaminated water.
TECHNICAL DATA
Output
3 hk/3600 rpm
Capacity
233 l/min
Connection
Ø 40 mm
Max. suction height
9 m
Water lift
23 m
Max. particle size
4,5 mm
Fuel
90 octane unleaded
Oil
SAE 15W–40
Oil volume
0.4 litres
Dimension
47 x 31 x 41 cm
Weight
18 kg
Sound pressure level, LpA
87 dB(A)
Measured Sound power level, LwA
96 dB(A)
Guaranteed Sound power level, LwA
99 dB(A)