background image

© 2015 Medivators Inc. MI02-0107/L

MEDIVATORS Website “Resource Center”

Go to: www.medivators.com, Select “Resource Center” and “User Library” for detailed user guides and hook-up  
information, report forms and logs, and product bulletins

MEDIVATORS Technical Support Toll Free:  Phone: 1-800-444-4729 

·

 FAX: 1-866-421-7696 

www.medivators.com

Manufactured in the USA by:
Medivators Inc. 
14605 28th Avenue North
Minneapolis, MN 55447 USA
Toll Free:  +1.800.444.4729

Medivators BV
Sourethweg 11
6422PC Heerlen
The Netherlands
Tel:  +31.45.5.471.471

Cantel Medical Asia/Pacific Pte Ltd
1A International Business Park
#05-01 Singapore 609933
Tel:  +65.6227.9698

Cantel Medical Devices (China) Co. Ltd.
Unit 804-805, Innov Tower Block A,
Hongmei Road, Xuhui 200233 Shanghai
Tel: +86 21 60161380
Fax: +86 21 612109136

Summary of Contents for CER

Page 1: ...5 to 3 GPM 9 4 LPM to 11 4 LPM filter system The cold water supply should not exceed 110 F 43 C FILTRATION SYSTEM NOTE Endoscope manufacturers recommended that endoscopes not be exposed to temperatures above 130 F 55 C NOTE A water shut off valve is required before the filter assembly It should be accessible to the users NOTE THE WATER SUPPLY IS REQUIRED TO BE TURNED OFF WHEN NOT IN USE 1 2 3 Gaug...

Page 2: ...r reorder CF01 0018 Filter Wrench CW03 0000 Stainless Steel Hose CH06 0000 Male quick connect fitting MC10 0042 Female Quick Connect MC10 0043 NOTE Do not remove the Male Female quick connectors in Figure 1 These are required to disinfect the filters and water line INSTALLATION 4 15 inches 16 inches Depth of unit is approximately 6 inches Figure 2 Water Filtration System Dimensions 2 ...

Page 3: ...ould be changed every three months even if water pressure is good The final filter should be changed at a minimum every six months even if the water pressure is good FILTER REPLACEMENT The accumulation of particles in a filter can cause the water pressure to drop below the minimum required level 40 PSI This depends on water quality which cannot be guaranteed by MEDIVATORS The pressure drop across ...

Page 4: ...ansfer pump into a one gallon container of high level disinfectant Press START on the reprocessor Turn on the transfer pump until the disinfectant solution starts flowing continuously in the basin Press STOP on the reprocessor Turn off the transfer pump Allow the reprocessor and the filters to soak for the time recommended on the product label of the high level disinfectant for high level disinfec...

Page 5: ...ctant and replace on header see Filtration Replacement Allow the filters to soak for the time recommended on the product label of the high level disinfectant for high level disinfection Turn on water supply to the filtration system Press START and allow the wash cycle to run in order to rinse the disinfectant out of the system When all of the water has drained press STOP 5 ...

Page 6: ...29 FAX 1 866 421 7696 www medivators com Manufactured in the USA by Medivators Inc 14605 28th Avenue North Minneapolis MN 55447 USA Toll Free 1 800 444 4729 Medivators BV Sourethweg 11 6422PC Heerlen The Netherlands Tel 31 45 5 471 471 Cantel Medical Asia Pacific Pte Ltd 1A International Business Park 05 01 Singapore 609933 Tel 65 6227 9698 Cantel Medical Devices China Co Ltd Unit 804 805 Innov To...