background image

111-0063-00 (Doc 556M) 

Page 1 of 8 

ISSUE H 

18/03/2021 

 

 

 

 

INSTRUCTIONS FOR USE 

OXYGEN DEMAND VALVE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAGE 

 

 

1. SYMBOLS 

 

 

 

 

 

 

 

 

 

2. INTENDED USE OF DEVICE  

 

 

 

 

 

 

3. TECHNICAL DESCRIPTION   

 

 

 

 

 

 

4. WARNINGS 

 

 

 

 

 

 

 

 

 

5. INSTRUCTIONS FOR USE   

 

 

 

 

 

 

6. CLEANING AND DISINFECTION   

 

 

 

 

 

7. MAINTENANCE 

 

 

 

 

 

 

 

 

8. SERIAL NUMBER 

 

 

 

 

 

 

 

 

9. PRODUCT LIFE SPAN 

 

 

 

 

 

 

 

10. SPECIFICATION 

 

 

 

 

 

 

 

 

11. SPARE PARTS  

 

 

 

 

 

 

 

 

12. RELEVANT APPLICABLE STANDARDS   

 

 

 

      COMPANY DETAILS   

 

 

 

 

 

 

 

READ THESE INSTRUCTIONS BEFORE USING THE EQUIPMENT 

Summary of Contents for OXYGEN DEMAND VALVE

Page 1: ...NTENDED USE OF DEVICE 2 3 TECHNICAL DESCRIPTION 2 4 WARNINGS 3 5 INSTRUCTIONS FOR USE 4 6 CLEANING AND DISINFECTION 5 7 MAINTENANCE 5 8 SERIAL NUMBER 6 9 PRODUCT LIFE SPAN 6 10 SPECIFICATION 6 11 SPAR...

Page 2: ...pieces require a 22mm female connection complying with BS EN ISO 5356 1 2015 2 TECHNICAL DESCRIPTION The principle of operation of the demand valve is similar to the original design of equipment used...

Page 3: ...8 ISSUE H 18 03 2021 The demand valve has been specifically designed to be used with low cost single use generic mouth piece and filter systems that are widely available using standard connections th...

Page 4: ...imes 4 9 The demand valve hose is fitted with medical gas specific connectors Do not interfere or modify the connector Particular attention must be paid during any form of maintenance to ensure that t...

Page 5: ...eleased 5 5 It is strongly advised to use a single use filter with the Demand Valve to minimise the risk of contamination of the device and a subsequent cross contamination between users Connect a uni...

Page 6: ...ice must be tested If required B N O S Meditech Ltd can advise on suitable test equipment 7 3 For Demand Valves in frequent use for example an Ambulance Service or a Maternity Unit personnel trained t...

Page 7: ...ment Compatibility with Oxygen BS EN ISO 5359 2014 A1 2017 Low pressure hose assemblies for use with medical gases BS 5682 2015 Probes quick connectors for use with medical gas pipeline systems BS EN...

Page 8: ...actured by B N O S Meditech Ltd 9 Fifth Avenue Bluebridge Ind Est Halstead Essex CO9 2SZ England Tel 44 0 1787 479475 Fax 44 0 1787 477747 E mail sales meditech uk com www meditech uk com EC Represent...