• Device will not switch on (LED not illuminating):
Plug in the plug; Check power circuit, socket and fuse.
• No mist:
Fill water tank.
• No mist although tank full:
Close the lid properly
• Mist intensity too weak:
Too much residue in the water canister, clean the ultrasonic trans-
ducer/water too dirty, replace.
• White deposits:
Use clean water or at least 1/2 distilled water / 1/2 fresh tap water.
• Unusual smell:
Polluted or stagnant water, clean the tank and fill up with fresh water.
• Unusual noise:
Insufficient water in the tank, fill up with water/device is not on a solid
surface, place on a stable and level surface.
If a fault cannot be remedied using the described method, please contact
your service centre.
3.6
Faults
and
Fault
Remedy-
ing
4 Miscellaneous
• During everyday use it is advisable to give the device a thorough clean-
ing at least every three days. Also clean device before and after long
storage periods.
• Before cleaning the device, make sure that it is turned off and the mains
plug is removed from the socket.
• Remove the water tank from the device and empty it.
• Clean the outside of the unit with a soft, damp cloth.
• Please do not use any aggressive substances for cleaning, such as
scouring cream or other detergents, as these may damage the sur-
faces and reduce the atomisation effect.
• You can rinse out the water tank with hot water (>65 °C) or an alcohol
of at least 75 % vol. The atomiser chamber should be cleaned using an
alcoholsoaked cloth and cotton bud. Take care to ensure that no water
gets inside the humidifier.
• The ultrasound generator is the most sensitive component in the de-
vice. It is important for it to be kept clean and handled with care. Use
e.g. a cleaning brush to remove all the residue and dirt particles. Never
clean the ultrasound generator using metal objects.
• If you do not intend to use the unit for an extended period of time,
empty any remaining water from the tank and dry off the unit.
• Store the unit in a cool, dry place, preferably in its original packaging.
• Remove cap from underside of the water tank and store separately to
prevent sleeve gasket from sticking.
4.1
Clean-
ing and
mainte-
nance
Summary of Contents for 60052
Page 97: ...91 1 GR LOT II...
Page 98: ...92 1 GR 8...
Page 99: ...93 1 GR MEDISANA 2...
Page 100: ...94 1 2 GR MEDISANA 2 AH 661 MEDISANA MEDISANA AH 661 1 MEDISANA AH 661 1 2 1...
Page 101: ...95 GR 2 3 40 55 30 m 2 2 55 3 MEDISANA A 2 3 2 3 1...
Page 103: ...97 3 4 GR LED 1 2 1 2 3 6 4 65 C 75 4 1...
Page 104: ...98 4 GR 4 1 1 25 g 500 ml 60 C 3 4 2 4 3...
Page 106: ...100 MEDISANA GmbH Jagenbergstra e 19 41468 NEUSS 1 MEDISANA 2 3 4 5 5 GR...
Page 107: ...101...
Page 108: ...60052 West 08 2018 Ver 1 7 MEDISANA GmbH Jagenbergstra e 19 41468 NEUSS Deutschland...