background image

2

IMPORTANT SAFETY INSTRUCTIONS:

WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE PRESENT, BASIC SAFETY  

PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:

READ ALL INSTRUCTIONS BEFORE USING.

DANGE

R – 

TO REDUCE THE RISK OF ELECTRIC SHOCK:

   Always unplug the air purifier from the electrical outlet immediately after using and before  

cleaning or replacing filters.

   Keep cord away from heated surfaces.

   Always place the air purifier on a firm, level surface.

   Always place the air purifier at least 3 feet from heat sources such as 

stoves, radiators, or heaters.

   DO NOT reach for an appliance that has fallen into water. Unplug it immediately.

   DO NOT place or store appliance where it can fall or be pulled into a tub or sink.

   DO NOT place in or drop into water or other liquid.

   Keep dry — DO NOT operate in wet or moist conditions.

   Check your air purifier cord and plug connections. Faulty wall outlet connections or loose plugs can 

cause the outlet or plug to overheat. Be sure the plug fits tightly in the outlet.

NOTE: 

This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock, this 

plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the 

plug. If it still does not fit, contact a qualified electrician.

DO NOT attempt to defeat this safety feature. To do so could result in an electric shock hazard.

WARNIN

G –

 TO REDUCE INJURY TO PERSONS:

   Always unplug the air purifier when not in use.

   Do not operate the air purifier with a damaged cord or plug, or has been dropped or damaged in any 

manner. Contact to www.medifyair.com for examination, electrical or mechanical adjustment, or repair. 

   This air purifier is not intended for use in bathroom, laundry areas, and similar moist indoor locations. 

   Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not 

route cord under furniture or appliances. Arrange cord away from traffic areas where it can be tripped over.

 

LIFETIME WARRANTY:

IF FILTERS ARE REPLACED ON TIME WITH GENUINE MEDIFY REPLACEMENT FILTERS.

Summary of Contents for MA-45WM

Page 1: ...READ AND SAVE THESE INSTRUCTIONS INSTRUCTION MANUAL AND WARRANTY INFORMATION MA 45WM AIRPURIFIER MA 45WM Rev 11 08 21 ...

Page 2: ... the outlet or plug to overheat Be sure the plug fits tightly in the outlet NOTE This appliance has a polarized plug one blade is wider than the other To reduce the risk of shock this plug is intended to fit only one way in a polarized outlet If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician DO NOT attempt to defeat this safety f...

Page 3: ...ual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons DO NOT use outdoors SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE UNIQUE FEATURES SPECIFICATIONS GENUINE MEDIFY TRUE HEPA H13 FILTRATION SYSTEM TRUE HEPA H13 FILTRATION Removes up to 99 9 of airborne particles as small as 0 1 microns such as allergens pollen dust germs pet dander odor mo...

Page 4: ... 550 sf every 15 min and up to 1100 sf every 30 min Portable air purifiers will be more effective in rooms where all the doors and windows are closed This air purifier will purify the air up to 550 sf every 15 min and up to 1100 sf every 30 min assuming an 8 FT 2 43 M ceiling on high speed in a closed room ...

Page 5: ...the fan speed setting the faster the air will be purified To select or change fan speed press the fan speed button until the desired setting is reached TIMER The Air Purifier can be programmed to turn off after a preset amount of time Press the button to program the timer Each press will add one hour up to a total of 12 hours Keeping the button pressed will automatically increase to 12 hours 1 hou...

Page 6: ...l the tabs to remove the old filter FILTER REPLACEMENT Filter Indicator Light when it is time to replace the True HEPA H13 filter based on the air purifier s hours of use a reminder will appear on the LED display to alert you to change the filters before further use REPLACING THE TRUE HEPA H13 FILTER For optimal performance replace every 2500 hours under normal usage conditions Once the filter has...

Page 7: ...lter Tabs facing out 5 Align the tabs at the bottom of the grille overs with the unit Gently push the grille covers until they snap back into place 6 Plug the power cord into a standard AC outlet Press and hold the dimmer button for 3 seconds to reset the indicator ...

Page 8: ...ocation selection must be able to bear the weight of the product and easy to operate maintain filter replacement etc Attach the base to the wall For solid concrete walls install as shown in the picture below For wood walls install as shown in the picture below Fix the bracket to the MA 45WM unit No specification Quantity A 4 B 4 C 10mm 4 D 4 E M6 20 4 F M4 50 2 1 Preparations before installation 2...

Page 9: ...9 Fix the bracket to the MA 45WM unit Attach the MA 45WM unit to the wall ...

Page 10: ...the True HEPA H13 filter back into the air purifier and close grille 4 Plug the power cord into a standard AC outlet FOR BEST PERFORMANCE Clean off the outside of the unit with a dry cloth as needed NEVER use water wax polish or any chemical solution to clean the outside of the unit Clean off the grille cover using a damp cloth or the brush attachment of your vacuum as needed Replace the True HEPA...

Page 11: ...vel or securely mounted to the wall Place the unit on flat level surface or mount the unit securely on the wall Replace filter light remains lit after filter replacement The replace filter indicator needs to be reset Press and hold the DIMMER button for 3 seconds until the replace filter light turns off TROUBLESHOOTING This product earned the ENERGY STAR by meeting strict energy efficiency guideli...

Page 12: ...y offers a lifetime warranty for parts and service as long as you are on record as having purchased Genuine Medify Replacement Filters as directed every 2500 hours of use See website for details and easy online registration Medify Air 1325 SW 30TH AVENUE DEERFIELD BEACH FL 33442 www medifyair com Contact info medifyair com Phone 888 258 1008 ...

Reviews: