HAND DRYERS

E05 / E05C / E05CS / E05B

E05A / E05AC / E05ACS / E05AB 

INSTALLATION AND OPERATING MANUAL 

distributed by 

 RESTROOM DIRECT       704 . 937. 2673      

www.

RestroomDirect

.com

Summary of Contents for E05

Page 1: ...www mediclinics com HAND DRYERS E05 E05C E05CS E05B E05A E05AC E05ACS E05AB INSTALLATION AND OPERATING MANUAL distributed by RESTROOM DIRECT 704 937 2673 www RestroomDirect com ...

Page 2: ...n order to avoid any electric shock risk The device must be fixed out of reach of a water source in order to fulfil the security distances marked into the current IEC standards and as the following figure shows Be careful because local installation requirements can ask more than 1 m of safety distance Take into account these local requirements as well Hairdryers must be fixed out of reach of a per...

Page 3: ... similar methods is forbidden by the European safety standards Dismantling for installation The appliance is supplied with the two lower screws screwed to the base that secures the cover from the inside The cover should be removed in the following manner 1 Screw the lower screws in a clockwise fashion CW with the supplied special tool until they are fully screwed in place see figure 1 2 Remove the...

Page 4: ...ugs until they are flush with the surface see figure 6 2 Pass the electric cable from the wall through the entrance hole Ø 22 mm Ø 0 87 3 Screw in the four supplied screws to firmly secure the base of the dryer to the wall see figure 7 4 Connect the Neutral and Line N L wires to the terminal block and the A V cable to the earth connection screw Class I see figure 8 5 Installing the cover on the dr...

Page 5: ...ied personnel WARNING when the cover is removed live parts of the appliance are exposed Means for discconection with contact separations at least 3 mm 0 12 must be incorporated in the fixing wiring During the installation process the protection areas should be considered according to Norm VDE 0100 The hand dryer must only be installed on a closed surface such as a wall partition or similar Automat...

Page 6: ...ite automatic cover 2 RC94850 Chrome bright automatic cover 2 RC94870 Chrome satin automatic cover 2 RC94860 Varnished automatic cover 2 RC94815 Scroll fan 3 RC95777 IR sensor 4 RC94600 IR sensor visor 5 RC94604 Heating element 6 RC95760 Motor 7 RC94748 Brushes set 8 RC95750 Electronic timer 9 RC94730 BREAKDOWN LIST OF BASIC PARTS distributed by RESTROOM DIRECT 704 937 2673 www RestroomDirect com ...

Page 7: ...econds after that it stops and will be ready to work again Automatic models These models operate by hand detection If hands are held 8 12 cm 3 1 4 7 from the air outlet the hand dryer will automatically start up Immediately after the hands can be gradually taken away from the dryer and will continue drying up to a maximum distance of 15 20 cm 5 9 7 9 The machine will stop 2 3 seconds after use Thi...

Page 8: ... mm 0 2 6 Carefully remove any dust from the electronic circuit using a fine brush Check that there is no dust or other dirt on the hand detection sensors 7 In automatic models ensure that the IR LED visor is clean and check that it is completely transparent 8 Once all maintenance operations have been completed replace the cover see the section Installation in the manual and then reconnect the mai...

Page 9: ...RIVATPERSONEN IN DER EUROPÄISCHEN GEMEINSCHAFT Das von Ihnen erworbene Produkt ist unter Verwendung hochwertiger Materialien und Bauteilen entwickelt und hergestellt worden die wiederverwertet und verwendet werden können Wenn ein Produkt mit dem nebenstehenden Symbol ein durchgestrichener Müllcontainer auf Rädern gekennzeichnet ist dann bedeutet dies dass dieses Produkt der Europäischen Richtlinie...

Page 10: ...ICS S A Industria 54 E 08025 BARCELONA SPAIN Tel 34 934 464 700 Fax 34 933 481 039 info mediclinics com www mediclinics com 20 11 13 COD 94915 distributed by RESTROOM DIRECT 704 937 2673 www RestroomDirect com ...

Reviews: