Wrap the bottom adhesive around the digit, being careful not to cover the nail.
Fold the sen
sor’s top over the digit, making sure the light source is directly over and in-line with
the detector. Wrap the adhesive around the finger or toe to secure the sensor. Route the cable
along the palm or the bottom of the foot, and secure with adhesive tape if necessary.
Connect the sensor to the device: insert the connector with the arrow on the connector face-up and check the proper functioning of the
sensor according to the previous instructions.
WARNING
Do not twist the cable or use excessive force when using, connecting, disconnecting, or storing the sensor.
Avoid over tightening the adhesive tape; a sensor wrapped too tightly can produce inaccurate saturation measurements.
To reduce chances of entanglement it is recommended to fasten the cable to the wrist with a bandage.
2.14
Testing without patient data
This function is available in Doctor Mode only, allowing the user to perform spirometry and oximetry testing without inserting any data related to the
patient being tested.
The user may access this function by touching the
icon on the main screen.
Within the screen area the user may access the following functions:
spirometry test
oximetry test
walk test
sleep oximetry
send data via Bluetooth
WARNING
Spirometry test results do not include any automatic interpretation compared with the predicted values as no patient anthropometric
data was previously included.
For oximetry testing including the walk test please refer to paragraph 3.13.1 and 3.13.3.
3.
DATA TRANSMISSION
WARNING
Please read carefully and make sure to have properly understood the instructions before commencing the data trasmission.
WARNING
The Bluetooth wireless communication is intended as an add-on function. In case of Bluetooth transmission failure, we recommend the
use of more reliable USB technology.
3.1
Data Transmission via Bluetooth to a SERVER by cell phone
To enable this function please contact the manufacturer.
3.2
Data transmission via Bluetooth for printing
WARNING
Check if the Bluetooth function is available in the device, this function is an option in some models.
Printing data from the patient management function will only work with a Bluetooth embedded printer or with the use of a USB adaptor
installed on the printer, thus enabling a Bluetooth connection.
The Bluetooth system enables
SPIRODOC
to transfer test data directly to a Bluetooth enabled printer. The procedure is listed below:
3.2.1
How to print a test saved in the database
From the main screen touch the
icon
Select a search method
Select the test session in which the test of interest was performed
Upon entering the test session select the test and touch the
icon.