The layout for the Common Config region in Flash is shown in Table 16. These items are:
•
loaded when MT7681 calls
load_com_cfg()
.
•
reset by calling
reset_com_cfg()
.
Offset
Section
Size
(Byte)
DEC
Offset
0x18000
Common Info Stored Flag
1
0
0x18001
Boot Firmware Index:
(0=station mode 1=AP mode 2=Recovery mode)
1
1
0x18002
Firmware Update Status
1
2
0x18003
I/O Mode select
1
3
0x18004
Reserved 1
20
4
0x18018
UART Baud rate
4
24
0x1801C
UART Data bits
1
28
0x1801D
UART Parity bits
1
29
0x1801E
UART Stop bits
1
30
0x1801F
Reserved 2
20
31
0x18033
TCP/UDP, Server/Client Select (Bitmap)
1
51
0x18034
TCP Server Port (2Bytes)
2
52
0x18036
TCP Client Port (2Bytes)
2
54
0x18038
UDP Server Port (2Bytes)
2
56
0x1803A
UDP Client Port (2Bytes)
2
58
0x1803C
IP Type select (0:Static / 1: Dynamic)
1
60
0x1803D
Static IP
4
61
0x18041
Subnet Mask (4 Bytes)
4
65
0x18045
DNS Server IP (4 Bytes)
4
69
0x18049
Gateway IP (4 Bytes)
4
73
0x1804D
IoT Server IP (4 Bytes)
4
77
0x18051
IoT Sever Domain Name (128 Bytes)
128
81
0x180D1
Reserved 3
20
209
0x180E5
Cmd_Password (4 Byte)
4
229
0x180E9
Reserved 4
x
233