Hardware Installation Guide - Mediatrix Sentinel
22
LED Name
Description
• Green, steady On: No
network traffic
• OFF: Not connected
PRI Connection (RJ-45)
Caution:
Always use standard telecommunication cables with a minimum of 26 AWG wire gauge.
PRI connections use two pairs of wires: one pair for transmission and the second pair for reception. It is wired
so that pins 1 & 2 are on one twisted pair and pins 4 & 5 are on a second pair according to common wiring
standards which meet the TIA/EIA 568A and 568B requirements.
Pin #
NT Mode
TE Mode
1
Transmit #2 (+)
Receive #2 (+)
2
Transmit #1 (-)
Receive #1 (-)
3
Not connected
Not connected
4
Receive #2 (+)
Transmit #2 (+)
5
Receive #1 (-)
Transmit #1 (-)
6
Not connected
Not connected
7
Not connected
Not connected
8
Not connected
Not connected
BRI S/T Connection (RJ-45)
Caution:
Always use standard telecommunication cables with a minimum of 26 AWG wire gauge.
BRI S/T connections use two pairs of wires: one pair for transmission and the second pair for reception. It
is wired so that pins 3 & 6 are on one twisted pair and pins 4 & 5 are on a second pair according to common
wiring standards which meet the TIA/EIA 568A and 568B requirements.